Finden Sie schnell kabe für Ihr Unternehmen: 3141 Ergebnisse

BIRTFLEX-EF 656

BIRTFLEX-EF 656

PVC INSULATED, , EXTRA FLEXIBLE, HIGH TEMPERATURE OIL RESISTANT CONTROL CABLES These high temperature 90oC grade, oil resistance high-flexibility control cables are designed for applications where cable flexibility is needed. These cables are used for instrumention ,control and connecting of control units in mechanical tool construction, conveyor and assembly lines, production lines, any areas where continuous bending loads for free movement without tensile load forced movement in the cable trailing chain is required. Conductor: Extra flexible copper wires, plain; IEC 60228 Class 6, TS/DIN EN 60228 Class 6 Insulation: PVC compound ,90o grade, TI3 Core identification: Acc. to TS/DIN EN 50334 black cores with white numerals with green/yellow from 3 cores Lay-up: Cores laid up in layers of shorten optimum pitch Separator: Textile bandaging Outer sheath: Oil and flame resistant PVC compound, 90oC Sheath colour: RAL 7001,Grey Standard: TS HD 21.13 S1, DIN VDE 0281-13TS HD 21.12 S1, DIN VDE 0281-12 (Designed according to) Insulation resistance: Min. 50 MΩ.km Rated voltage Uo/U: 300 / 500V Test voltage: 4000 V Temperature range: Fixed: - 40 oC ~ + 90 oC; Mobile: - 5 oC ~ + 90 oC Min. bending radius: Fixed: 4 x D; Mobile: 7,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1 Oil test: IEC 60811-2-1
KE401, IT-Leitungssucher Kit

KE401, IT-Leitungssucher Kit

Die Leitungssucher-Kits bestehen aus EasyTest und Probe und ermöglichen jedem Techniker ohne zeitaufwändige Abisolierarbeiten jede Art von Kabel, Adern und Adernpaare in kürzester Zeit berührungslos zu finden. Dabei werden Fehler wie Vertauschungen, Überziehungen, Unterbrechungen und andere Störungen im Kabel erkannt. Die Kabelsucher sind für alle Arten von Kabeln wie Telefonkabel, Klingelleitungen, Datenkabel aller Klassen, Koax-Kabel und spannungsfreie elektrische Leitungen einsetzbar. Die Einspeisung des Suchsignals auf aktive Telekommunikationsleitungen mit bis zu 100 V Spannung sowie zahlreiche weitere Funktionen machen diese Geräte zum beliebten Werkzeug der Installationsbetriebe. Produkt-Highlights KE401 IT Kit: • Für IT & Telefonverkabelungen und Adernpaaridentifizierung • RJ11 / RJ45 Stecker & Krokodilklemmen • Datenport-Test mit Portfinder-Funktion • ISDN-Signal Identifikation mit Probe • Fremdspannungsschutz bis 120 V AC Artikelnummer: D140C
RE-2Y(St)Y-fl-MP

RE-2Y(St)Y-fl-MP

INSTRUMENTATION CABLES, BS 5308 PART 1 TYPE 1SİNGLE & MULTİ-PAİR, PE INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 1,0 mm2 solid,, 0,50 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type03 Core identification: According to BS 5308 Part 1 colour coded, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Rated voltage: 300/500V Standard: BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m (≤2 pairs),max. 75 pF/m (all other pairs), 1,0 mm2 : max. 115 pF/m (≤2 pairs),max. 75 pF/m (all other pairs), 1,5 mm2 : max. 120 pF/m (≤2 pairs),max. 85 pF/m (all other pairs) Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
RE-2G(St)H-CI  FE180 MP

RE-2G(St)H-CI FE180 MP

HALOGEN-FREE FIRE RESISTANT (CI) INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, SILICONE INSULATED, COLLECTIVE SCREENED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used on the basis of a fixed operating mode, can continue with the supply of a power under the existing fire conditions and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: Special silicone rubber compound Core identification: Black / Blue cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath: HFFR compound, EN 50290-2-27 L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Standard: TS/DIN EN 50288-7, (Designed according to) Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range: operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Circuit integrity (CI): IEC 60331 , VDE 0472-814, BS 6387 Cat. CWZ Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2
BIRTFLEX-EF 659-C-PUR

BIRTFLEX-EF 659-C-PUR

PP INSULATED,PUR SHEATED EXTRA FLEXIBLE SCREENED OIL RESISTANT CONTROL CABLES These screened, oil, cold and extreme mechanical loads resistance , high-flexibility control cables are designed for applications where cable flexibility is needed. These type is more economical than BIRTFLEX-EF 6512-C. These cables with high service periods, are used for instrumention ,control and connecting of control units in mechanical tool construction, conveyor and assembly lines, production lines any areas where continuous bending loads for free movement which has no pulling force ,with low tensile load forced movement in the cable trailing chain is required and at heavy conditions, dry, ambitient, cold and wet places.The screen above the inner sheat protects against external interference pulses and ensures an interference-free transmission, and transfer impedance is max. 250 ?/km at 30MHZ Conductor: Extra flexible copper wires, plain; IEC 60228 Class 6, TS/DIN EN 60228 Class 6 Insulation: PP compound, 9Y Core identification: Numbered cores or colour coded cores Lay-up: Cores laid up in layers of shorten optimum pitch Separator: Textile bandaging Inner Sheath: Speacial compound, RAL 7001,Grey Screen: Braid of tinned copper wires, 85% coverage Outer sheath: PUR compound, 11YM1 Sheath colour: RAL 7001, Grey Standard: TS HD 21.13 S1, DIN VDE 0281-13DIN VDE 0282-10 (Designed according to) Insulation resistance: Min. 50 MΩ.km Rated voltage Uo/U: 300 / 500V Test voltage: 2000 V Temperature range: Fixed: - 30 oC ~ + 70 oC; Mobile: - 5 oC ~ + 70 oC Min. bending radius: Fixed: 4 x D; Mobile: 7,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1 Oil test: IEC 60811-2-1 Transfer impedance: Max. 250 Ω/km at 30MHZ EMC: ELECTROMAGNETIC COMPATIBILITY
RE-2Y(St)2YSWAY-fl-MP

RE-2Y(St)2YSWAY-fl-MP

INSTRUMENTATION CABLES, BS 5308 PART 1 TYPE 2SİNGLE & MULTİ-PAİR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 1,0 mm2 solid,, 0,50 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type03 Core identification: According to BS 5308 Part 1 colour coded, *Upon request ; Black / White cores numbered 1-1-1, 2-2-2,… Pair: Two conductors twisted to a pair Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m (≤2 pairs),max. 75 pF/m (all other pairs), 1,0 mm2 : max. 115 pF/m (≤2 pairs),max. 75 pF/m (all other pairs), 1,5 mm2 : max. 120 pF/m (≤2 pairs),max. 85 pF/m (all other pairs) Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
RE-Y(St)Y-fl-MP

RE-Y(St)Y-fl-MP

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 1SİNGLE & MULTİ-PAİR, PVC INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: According to BS 5308 Part 2 colour coded, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 1 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
RE-Y(St)YSWAY-PIMF

RE-Y(St)YSWAY-PIMF

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 2MULTİ-PAİR, PVC INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: White / blue ; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PVC compund, TM1, BS 7655, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 2 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Flame retardance test: IEC 60332-1 & BS EN 60332-1 Min. bending radius: 6 x D
BIRTFLEX 5511-PUR

BIRTFLEX 5511-PUR

PVC INSULATED, PUR SHEATED CONTROL CABLES These flexible PUR sheathed connecting cables are more used in mechanical engineering for instrumentation and control equipment for tooling machinery production lines and flexible applications for free movement with low tensile load at heavy conditions, dry, ambitient and wet places. These cables can be used at outdoor applications at fixed installations. Conductor: Flexible copper wires, plain; IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: PVC compound , TI2 Core identification: Acc. to TS/DIN EN 50334 black cores with white numerals with green/yellow from 3 cores Lay-up: Cores laid up in layers of optimum pitch Inner Sheath: PVC compound Outer sheath: PUR compound, 11YM1 Sheath colour: RAL 7001,Grey Standard: TS HD 21.13 S1, DIN VDE 0281-13 VDE 0245-102, DIN VDE 0282-10 (Designed according to) Insulation resistance: Min. 50 MΩ.km Rated voltage Uo/U: 300 / 500V Test voltage: 4000 V Temperature range: Fixed: - 40 oC ~ + 70 oC; Mobile: - 5 oC ~ + 70 oC Min. bending radius: Fixed: 4 x D; Mobile: 10 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1
RE-2Y(St)2YSWAY-fl-TIMF

RE-2Y(St)2YSWAY-fl-TIMF

INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , ,0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type 03 Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Two conductors twisted to a pair TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
BIRTFLEX 552-C / YSLCY

BIRTFLEX 552-C / YSLCY

PVC INSULATED, SCREENED CONTROL CABLES Conductor: Flexible copper wires, plain; , IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: PVC compound , TI2 Core identification: Acc. to TS/DIN EN 50334 black cores with white numerals with green/yellow from 3 cores Lay-up: Cores laid up in layers of optimum pitch Separator: Polyester tape Screen: Braid of tinned copper wires, 85% coverage Outer sheath: PVC compound, TM2 Sheath colour: RAL 7001, Grey Standard: TS HD 21.13 S1, DIN VDE 0281-13 VDE 0245-102 Insulation resistance: Min. 20 MΩ.km Rated voltage Uo/U: 300 / 500V Test voltage: 4000 V Temperature range: Fixed: - 40 oC ~ + 70 oC; Mobile: - 5 oC ~ + 70 oC Min. bending radius: Fixed: 4 x D; Mobile: 7,5 x D
BayCom®  A-02YSTF(L)H  StIII

BayCom® A-02YSTF(L)H StIII

Flammwidrige Anschluss- und Verbindungskabel in Ortsnetzen und in Nebenstellenanlagen, zum Fernsprechen und zur Übertragung von Daten. BayCom® CPR Eca A-02YSTF(L)H sind flammwidrige Telekommunikationskabel, die als Anschluss- und Verbindungskabel in Ortsnetzen und in Nebenstellenanlagen, zum Fernsprechen und zur Übertragung von Daten verwendet werden. Sie sind geeignet für die Verlegung in Erde und in Kabelkanälen, sowie zum Einziehen in Kabelrohre. Die Klassifizierung nach BauPVO Eca ermöglicht zudem die Verlegung in Gebäuden ohne besonderen Sicherheitsbedarf.
BIRTFLEX 515

BIRTFLEX 515

PVC INSULATED,OIL RESISTANT, 0,6/1 kV CONTROL CABLES These oil and flame resistant, rated voltage 0,6/1 kV, flexible connecting cables are used in mechanical engineering for instrumentation and control equipment for tooling machinery production lines and flexible applications for free movement without tensile load in dry, moist and wet rooms. These cables are not used for outdoor or underground installation. Conductor: Flexible copper wires, plain; IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: PVC compound , TI2 Core identification: Acc. to TS/DIN EN 50334 black cores with white numerals with green/yellow from 3 cores Lay-up: Cores laid up in layers of optimum pitch Outer sheath: PVC compound, TM5 Sheath colour: RAL 9005, Black Standard: TS HD 21.13 S1, DIN VDE 0281-13 (Designed according to) Insulation resistance: Min. 50 MΩ.km Rated voltage Uo/U: 0,6/1 kV Test voltage: 4000 V Temperature range: Fixed: - 40 oC ~ + 70 oC; Mobile: - 5 oC ~ + 70 oC Min. bending radius: Fixed: 4 x D; Mobile: 12,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1 Oil test: IEC 60811-2-1
RE-2Y(St)YQY-fl MP

RE-2Y(St)YQY-fl MP

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, STEEL WIRE BRAIDED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the sheath, steel wire braid serves as protection against mechanical traverse loads and act as a magnetic screen against interference. The galvanised steel wires are free of corresion and oxidation.These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: PVC compound, EN 50290-2-22 Armour: Braid of galvanized steel wires, aprx. %85 cov. Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm
BIRTFLEX 515 CY

BIRTFLEX 515 CY

PVC INSULATED,SCREENED OIL RESISTANT 0,6/1 kV CONTROL CABLES These oil and flame resistant, rated voltage 0,6/1 kV, flexible cables are used in mechanical engineering for instrumentation and control equipment for tooling machinery production lines and flexible applications for free movement without tensile load and witout forced movement, in dry, moist and wet rooms. The screen above the inner sheat protects against external interference pulses and ensures an interference-free transmission, and transfer impedance is max. 250 ?/km at 30MHZ. These cables are not used for outdoor or underground installation. Conductor: Flexible copper wires, plain; IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: PVC compound , TI2 Core identification: Acc. to TS/DIN EN 50334 black cores with white numerals with green/yellow from 3 cores Lay-up: Cores laid up in layers of optimum pitch Inner Sheath: PVC compound, TM2; RAL 7001,Grey Screen: Braid of tinned copper wires, 85% coverage Outer sheath: Oil and flame resistant PVC compound, TM5 Sheath colour: RAL 9005, Black Standard: TS HD 21.13 S1, DIN VDE 0281-13 (Designed according to) Insulation resistance: Min. 50 MΩ.km Rated voltage Uo/U: 0,6/1 kV Test voltage: 4000 V Temperature range: Fixed: - 40 oC ~ + 70 oC; Mobile: - 5 oC ~ + 70 oC Min. bending radius: Fixed: 6 x D; Mobile: 12,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1 Oil test: IEC 60811-2-1 Transfer impedance: Max. 250 Ω/km at 30MHZ EMC: ELECTROMAGNETIC COMPATIBILITY
BayCom® PE-ALT-FT ...x4x0,6

BayCom® PE-ALT-FT ...x4x0,6

Fernmeldekabel mit Sternviererverseilung, PE-Isolierung, ALT-Mantel, Stahlbandarmierung und einem PE-Außenmantel. Fernmeldekabel mit Sternviererverseilung, PE-Isolierung, ALT-Mantel, Flachdrahtarmierung und einem PE-Außenmantel Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
E-DAT modul Cat.6A 8(8) Buchse, (12 Stück)

E-DAT modul Cat.6A 8(8) Buchse, (12 Stück)

‧ modulare Anschlusseinheit Cat.6A, RJ45 ‧ Cat.6A Komponentenprüfung nach ISO/IEC 11801, DIN EN 50173-1, ANSI/TIA-568.2-D und IEC 60603-7-51, GHMT zertifiziert ‧ Einhaltung der Klasse EA nach ISO/IEC 11801, DIN EN 50173-1 ‧ getestet: Link bis 500 MHz ‧ für 10 GBit Ethernet (IEEE 802.3an), Remote Powering (PoE, PoE plus, UPoE und 4PPoE) und HDBaseT geeignet ‧ montagefreundlicher Anschluss der 2- bis 4-paarigen Datenleitung AWG 26/1 - 22/1 und Litzenleiter mit 7-drähtiger Cu-Litze AWG 26/7 - 22/7 an BTR 8fach IDC-Schneidklemmen ‧ Kennzeichnung der Adernbelegung T568A und T568B ‧ leichtes und schnelles Einlegen der Adernpaare in das E-DAT modul Ladestück ‧ Modulgehäuse aus Zinkdruckguss, veredelt ‧ Montage ohne Spezialwerkzeug ‧ Zugentlastung mit Kabelbinder am Modul ‧ Befestigungsmöglichkeit für Staubschutzklappe ‧ Einbauform: Modul ‧ Kabelzuführung 180° ‧ Lieferung in einer 12er Verpackung, nicht einzeln lieferbar
BayCom®  nonfire Metro

BayCom® nonfire Metro

speziell für den ÖPNV entwickelte hoch flammwidrige und querwasserdichte Telekommunikationskabel, insbesondere als Anschlusskabel in Ortsnetzen und in Nebenstellenanlagen. BayCom® nonfire B2ca Metro sind speziell für den ÖPNV entwickelte hoch flammwidrige und querwasserdichte Telekommunikationskabel, insbesondere als Anschlusskabel in Ortsnetzen und in Nebenstellenanlagen, zum Fernsprechen und zur Übertragung von Daten. Hochwertige Materialien ermöglichen nicht nur die Verwendung in Bauwerken und Bereichen mit hohem Brandsicherheitsbedarf, wie z.B. U-Bahn Tunnel, sondern auch im Freien und direkt in Erde. Geeignet für die Verlegung in Rohranlagen und Kabeltrögen, im Freien, auf Tragesystemen, in Installationsschächten und für fachgerechte Verlegearten in Tunneln, Gebäuden und Innenbereichen mit Publikumsverkehr. Erfüllen höchste Brandschutzanforderungen gem. BauPVO. Querwasserdicht für einen störungsfreien Betrieb.
RE-Y(St)YSWAY-fl

RE-Y(St)YSWAY-fl

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 2MULTİ-CORE, PVC INSULATED, COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: Up to 40 cores; yellow with black numbers and, word printed (1-40), (10,TEN); up to 80 cores;, black with yellow numbers and word printed, (1-40), (10,TEN) Lay-up: Cores laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PVC compund, TM1, BS 7655, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 2 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,0 Ω/km, 0,75mm2 : 26,0 Ω/km, 1,5mm2 : 12,1 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
BayCom® PE4D-ALT-CLE

BayCom® PE4D-ALT-CLE

Fernmeldekabel mit Sternviererverseilung, PE4-Isolierung (Foam-Skin), Quellgarnen und -vliesen als Längswasserschutz, ALT-Mantel, Stahlbandarmierung und einem halogenfreien, flammwidrigen und raucharmen Außenmantel.
RE-2YCY-fl-PIMF

RE-2YCY-fl-PIMF

INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: Braid of tinned Cu wires, 85% coverage Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
BayCom®  A-02YSTF(L)2YV

BayCom® A-02YSTF(L)2YV

Streckenfernmeldekabel Zur allgemeinen Verkabelung im Streckenbereich. Für das Legen in Erde, in Trogkanäle und Rohrkanäle entsprechend dem geltenden Regelwerk. Zur allgemeinen Verkabelung im Streckenbereich. Für den Einsatzfall Neubau als Nachfolgetypen der papierisolierten Kabel mit F-, TF-, TFS- und Koax-Aufbauelementen nach Dlk 1.01.106 der Deutschen Bahn AG. Für das Legen in Erde, in Trogkanäle und Rohrkanäle entsprechend dem geltenden Regelwerk. Alle Stammleitungen der Kabel sind mit den Stammleitungen vom jeweils selben Leiternenndurchmesser der Kabel nach Dlk 1.01.106 (Papier-Metallmantel-Kabel des bestehenden Netzes) stoßfrei zusammenschaltbar. Für einen leichten Umstieg von papierisolierten Fernmeldekabeln und eine effiziente Planung bei Neuanlagen nutzen sie unser Multisystem-Kabel-Tool - die einfachste Art die optimale Aderkombination zu finden! Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BIRTFLEX-EF 659-PUR

BIRTFLEX-EF 659-PUR

PP INSULATED, PUR SHEATED EXTRA FLEXIBLE OIL RESISTANT CONTROL CABLES These oil, cold and extreme mechanical loads resistance high-flexibility PUR sheated control cables are designed for applications where cable high flexibility is needed. These type is more economical than BIRTFLEX-EF 6512. These cables with high service periods, are used for instrumention ,control and connecting of control units in mechanical tool construction, conveyor and assembly lines, production lines, any areas where continuous bending loads for free movement which has no pulling force ,with low tensile load forced movement in the cable trailing chain is required and at heavy conditions, dry, ambitient, cold and wet places. Conductor: Extra flexible copper wires, plain; IEC 60228 Class 6, TS/DIN EN 60228 Class 6 Insulation: PP compound, 9Y Core identification: Numbered cores or colour coded cores Lay-up: Cores laid up in layers of shorten optimum pitch Separator: Textile bandaging, at each lay-up layer. Outer sheath: PUR compound, 11YM1 Sheath colour: RAL 7001, Grey Standard: TS HD 21.13 S1, DIN VDE 0281-13DIN VDE 0282-10 (Designed according to) Insulation resistance: Min. 50 MΩ.km Rated voltage Uo/U: 300 / 500V Test voltage: 2000 V Temperature range: Fixed: - 30 oC ~ + 80 oC; Mobile: - 5 oC ~ + 70 oC Min. bending radius: Fixed: 4 x D; Mobile: 7,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1 Oil test: IEC 60811-2-1
RE-2Y(St)2YSWAY-fl

RE-2Y(St)2YSWAY-fl

INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2SİNGLE & MULTİ-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , ,0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type03 Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…) Triple: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
BayCom®  AJ-02YSTF(L)2YDB2Y

BayCom® AJ-02YSTF(L)2YDB2Y

Induktionsschutzbewehrtes Streckenfernmeldekabel Zur allgemeinen Verkabelung im Streckenbereich. Für das Legen in Erde, in Trogkanäle und Rohrkanäle entsprechend dem geltenden Regelwerk. Zur allgemeinen Verkabelung im Streckenbereich. Für den Einsatzfall Neubau als Nachfolgetypen der papierisolierten Kabel mit F-, TF-, TFS- und Koax-Aufbauelementen nach Dlk 1.01.106 der Deutschen Bahn AG. Für das Legen in Erde, in Trogkanäle und Rohrkanäle entsprechend dem geltenden Regelwerk. Alle Stammleitungen der Kabel sind mit den Stammleitungen vom jeweils selben Leiternenndurchmesser der Kabel nach Dlk 1.01.106 (Papier-Metallmantel-Kabel des bestehenden Netzes) stoßfrei zusammenschaltbar. Für einen leichten Umstieg von papierisolierten Fernmeldekabeln und eine effiziente Planung bei Neuanlagen nutzen sie unser Multisystem-Kabel-Tool - die einfachste Art die optimale Aderkombination zu finden! Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
RE-2YCYSWAY-fl-PIMF

RE-2YCYSWAY-fl-PIMF

INSTRUMENTATION CABLES, EN 50288-7MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, It can be manufacture as RE-2Y(St)CYSWAY-PIMF upon request. Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: Braid of tinned Cu wires, 85% coverage Inner sheath: PVC compound, EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
BayCom®  PE-ALT-CLT  x4x1,5

BayCom® PE-ALT-CLT x4x1,5

Fernmeldekabel mit Sternviererverseilung, PE-Isolierung, ALT-Mantel, Stahlbandarmierung und einem PE-Außenmantel. Fernmeldekabel mit Sternviererverseilung, PE-Isolierung, ALT-Mantel, Stahlbandarmierung und einem PE-Aussenmantel Das Kabel ist für Verlegung im Erdreich oder außerhalb von Bauwerken vorgesehen und unterliegt damit nicht der Bauprodukteverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
BIRTFLEX-EF 6512-C-PUR

BIRTFLEX-EF 6512-C-PUR

TPE-E INSULATED,PUR SHEATED EXTRA FLEXIBLE SCREENED OIL RESISTANT CONTROL CABLES These screened, oil, cold and extreme mechanical loads resistance , high-flexibility control cables are designed for applications where cable flexibility is needed. These cables with high service periods, are used for instrumention ,control and connecting of control units in mechanical tool construction, conveyor and assembly lines, production lines any areas where continuous bending loads for free movement which has no pulling force ,with low tensile load forced movement in the cable trailing chain is required and at heavy conditions, dry, ambitient, cold and wet places. Conductor: Extra flexible copper wires, plain; IEC 60228 Class 6, TS/DIN EN 60228 Class 6 Insulation: Speacial compound, TPE-E Core identification: Acc. to TS/DIN EN 50334 black cores with white numerals with green/yellow from 3 cores Lay-up: Cores laid up in layers of shorten optimum pitch Separator: Textile bandaging Inner Sheath: Speacial compound, RAL 7001,Grey Screen: Braid of tinned copper wires, 85% coverage Outer sheath: PUR compound, 11YM1 Sheath colour: RAL 7001, Grey Standard: TS HD 21.13 S1, DIN VDE 0281-13DIN VDE 0282-10 (Designed according to) Insulation resistance: Min. 50 MΩ.km Rated voltage Uo/U: 300 / 500V Test voltage: 2000 V Temperature range: Fixed: - 50 oC ~ + 70 oC; Mobile: - 40 oC ~ + 70 oC Min. bending radius: Fixed: 4 x D; Mobile: 7,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1 Oil test: IEC 60811-2-1 Transfer impedance: Max. 250 Ω/km at 30MHZ EMC: ELECTROMAGNETIC COMPATIBILITY
BayCom®  S-YY  x2x0,6

BayCom® S-YY x2x0,6

Schaltkabel zur Übertragung von Nachrichten und Daten für Steuerungen, z. B. in Stellwerksanlagen bei Eisenbahnen für die Verbindung von Außenkabeln mit Baugruppen der Stellwerksanlage. BayCom® CPR Eca S-YY sind Schaltkabel zur Übertragung von Nachrichten und Daten für Steuerungen, z. B. in Stellwerksanlagen bei Eisenbahnen für die Verbindung von Außenkabeln mit Baugruppen der Stellwerksanlage und als Verbindung zwischen Gestellen und Rangierverteilern.<br /> Die Kabel sind zur besseren Lötbarkeit auch in verzinnter Ausführung erhältlich.
RE-Y(St)YSWAY-fl-MP

RE-Y(St)YSWAY-fl-MP

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 1SİNGLE & MULTİ-PAİR, PVC INSULATED, COLLECTİVE SCREENED,ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: According to BS 5308 Part 2 colour coded, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PVC compund, TM1, BS 7655, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 2 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1