RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF

RE-2Y(St)YSWAY-fl-TIMF & RE-2X(St)YSWAY-fl-TIMF

INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)YSWAY-fl-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHEDRE-2X(St)YSWAY-fl-TIMF,MULTI-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath (2Y): PVC compound, EN 50290-2-22 Inner sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-Y(St)YSWAY-fl-TIMF & RE-Yw(St)YwSWAYw-fl-TIMF

RE-Y(St)YSWAY-fl-TIMF & RE-Yw(St)YwSWAYw-fl-TIMF

INSTRUMENTATION CABLES, EN 50288-7MULTI-TRIPLE, PVC INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. For application of 105oC heat resistant, RE-Yw(St)YwSWAYw-TIMF cables are suitable. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Inner sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 190 pF/m, 0,75 mm2 : max. 190 pF/m, 1,0 mm2 : max. 190 pF/m, 1,3 mm2 : max. 200 pF/m, 1,5 mm2 : max. 200 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-Y(St)Y-fl-TIMF & RE-Yw(St)Yw-fl-TIM

RE-Y(St)Y-fl-TIMF & RE-Yw(St)Yw-fl-TIM

INSTRUMENTATION CABLES, EN 50288-7MULTİ-TRIPLE, PVC INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHED Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / White / Red; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 190 pF/m, 0,75 mm2 : max. 190 pF/m, 1,0 mm2 : max. 190 pF/m, 1,3 mm2 : max. 200 pF/m, 1,5 mm2 : max. 200 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-Y(St)YSWAY-fl & RE-Yw(St)YwSWAYw-fl

RE-Y(St)YSWAY-fl & RE-Yw(St)YwSWAYw-fl

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, PVC INSULATED, COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Outer sheath (Y): PVC compound, 105 oC grade; EN 50290-2-22 Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Inner sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 190 pF/m, 0,75 mm2 : max. 190 pF/m, 1,0 mm2 : max. 190 pF/m, 1,3 mm2 : max. 200 pF/m, 1,5 mm2 : max. 200 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)HSWAH & RE-2X(St)HSWAH MP

RE-2Y(St)HSWAH & RE-2X(St)HSWAH MP

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / Blue cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Standard: TS/DIN EN 50288-7 Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 500V Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
RE-2Y(St)Y-fl-TIMF & RE-2X(St)Y-fl-TIMF

RE-2Y(St)Y-fl-TIMF & RE-2X(St)Y-fl-TIMF

INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl-TIMF,MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl-TIMF,MULTI-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White / Red; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)Y-fl-PIMF & RE-2X(St)Y-fl-PIMF

RE-2Y(St)Y-fl-PIMF & RE-2X(St)Y-fl-PIMF

INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)Y-fl-PIMF,MULTİ-PAİR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHEDRE-2X(St)Y-fl-PIMF,MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / Blue cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP

RE-2Y(St)HSWAH&RE-2X(St)HSWAH-MP

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZH SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTİVE SCREENED, ARMOURED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: According to BS 5308 Part 1 colour coded , Note: Other core configurations manufactured upon request Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP

RE-2Y(St)HSWAH & RE-2X(St)HSWAH-MP

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-PAIR, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
RE-2Y(St)HSWAH-PIMF&RE-2X(St)HSWAH-PIMF

RE-2Y(St)HSWAH-PIMF&RE-2X(St)HSWAH-PIMF

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH-PIMF,SINGLE & MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOUR, LSZH SHEATHEDRE-2X(St)HSWAH-PIMF,SINGLE & MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED,ARMOUR, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / blue ; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Blackk Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF

RE-2Y(St)HSWAH-PIMF & RE-2X(St)HSWAH-PIMF

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-PIMF,MULTI-PAIR, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH-PIMF,MULTI-PAIR, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. PIMF Construction: Polyester tape above the pair, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White ; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White cores numbered 1-1, 2-2,…, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF

RE-2Y(St)HSWAH-TIMF&RE-2X(St)HSWAH-TIMF

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH-TIMF,SİNGLE & MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOUR, LSZH SHEATHEDRE-2X(St)HSWAH-TIMF,SİNGLE & MULTİ-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED,ARMOUR, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF

RE-2Y(St)HSWAH-TIMF & RE-2X(St)HSWAH-TIMF

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH-TIMF,MULTI-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH-TIMF,MULTI-TRIPLE, XLPE INSULATED, INDIVIDUAL & COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / Beyaz / Red; with numbered tape under, separator tape of the pair screen, Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
Easys Kabel für Ecklösung

Easys Kabel für Ecklösung

Easys Kabel für Ecklösung 9084790 Kabel für Ecklösung• Verhindert das gleichzeitige Öffnen von Schubkästen oder Frontauszügen bei über Eck angeordneten Korpussen Artikelnummer: E9084790 Gewicht: 0.004 kg
SY TEK DAMAR / SY SINGLE CORE

SY TEK DAMAR / SY SINGLE CORE

STEEL WIRE BRAID SHIP TYPE CABLES,SY- SINGLE CORE 300/500 V These cables are mainly used in permanent installations such as e.g. lighting, power cables in ships. They are very resistant to all conditions in the marine environment such as dry, wet and oil Steel wire braid serves as protection against mechanical traverse loads and act as a magnetic screen against interference. The galvanised steel wires are free of corresion and oxidation. Conductor: Plain Cu wires, flexible ,IEC 228-5 Insulation: PVC compound Screen: Braid of galvanised wires, approx. %85 coverage Outer sheath: Oil and flame resistant special PVC compound Sheath colour: Black Flame retardance test: IEC 60332-1 & EN 50265-2-1 Standard: Accoding to VDE 0250 Insulation resistance: >20 MΩ.km Rated voltage: 300/500 V Test voltage: 2000 V Temperature range: Fixed : - 30 oC ~ + 70 oC, Mobile : - 5 oC ~ + 50 oC Min. bending radius: 10 x D
PERFECT Kabelverschraubung Kunststoff metrisch

PERFECT Kabelverschraubung Kunststoff metrisch

Die PERFECT Kabelverschraubung aus Polyamid ist die passende Lösung zur Kabeldurchführung in verschiedensten industriellen Anwendungen. Eigenschaften: - integrierte Zugentlastung für Kabel und Leitungen - großer Dicht- und Klemmbereich - für Leitungen von 3 bis 42 mm - montagefreundlich - Temperaturbereich-20 °C / +100 °C (dynamisch) -40 °C (statisch, kurzzeitig) - Schutzart IP68 - 5 bar - Prüfnorm EN 62444 / UL 514B - viele Varianten und Zubehörteile verfügbar PERFECT PERFECT metric 50.6xx PAzzzz 50.6xx PAzzzz Material: Polyamid PA6 Schutzart: IP68 - 5 bar Für Kabeldurchmesser: 3-42 mm
Ex-Kabelverschraubung Polyamid

Ex-Kabelverschraubung Polyamid

Ex-Kabelverschraubung aus Kunststoff für den Einsatz in explosionsgefährdeten Bereichen. - für festverlegte Kabel - Gruppe (Zone) II 2 G (1, 2) / II 2 D (21, 22) - Kennzeichnung Ex e IIC Gb / Ex tb IIIC Db - Schutzart IP66 Für weitere Infos bitte Datenblatt herunterladen. Jacob Ex-cable gland GHG9601955R01zz GHG9601955R01zz Material: Polyamid PA6 Schutzart: IP66
Ex-Vergussmassen-Kabelverschraubungen ICG 653/UNIVERSAL

Ex-Vergussmassen-Kabelverschraubungen ICG 653/UNIVERSAL

Die HAWKE ICG 653/UNIVERSAL ist eine Vergussmassen-Kabelverschraubung für armierte und geschirmte Leitungen, bei der nach der Installation die Vergussmasse überprüft und wenn notwendig ausgebessert werden kann. Sie ist geeignet für alle Arten von Armierung und Schirmgeflechten, aber auch für nicht geschirmte/nicht armierte Leitungen und für Glasfaser-Anwendungen. Verfügbare Werkstoffe: Messing, Messing vernickelt, Edelstahl 1.4404, V4A, 316L, Aluminium Zündschutzarten: Ex db IIC Gb, Ex eb IIC Gb, Ex nR IIC Gc, Ex tb IIIC Db Einsetzbar in Zone 1, Zone 2, Zone 21, Zone 22 und in den Gasgruppen IIA, IIB and IIC. Explosionsschutz nach ATEX/IECEx Temperaturbereich: -60 °C / +80 °C Klemmbereich: 5,5 mm bis 78,0 mm Gewindearten: metrisch M20 bis M75, NPT 1/2" bis 3" Schutzarten: IP66, IP67, IP68 (30 Meter für 7 Tage), IP69, Deluge Protected DTS01, NEMA 4X HAWKE HAWKE UNIVERSAL ICG 653/UNIVERSAL
Ex d-Kabelverschraubung CSB/656N mit Vergussmasse für Schutzschlauch-Anbindung

Ex d-Kabelverschraubung CSB/656N mit Vergussmasse für Schutzschlauch-Anbindung

Die HAWKE CSB/656N Ex d-Kabelverschraubung mit Vergussmasse zum Anschluss eines Schutzschlauches oder einer Conduit-Verbindung Die HAWKE CSB/656N Ex d-Kabelverschraubung ist geeignet zum Anschluss eines Schutzschlauches oder einer Conduit-Verbindung. Die einzelnen Adern werden per Vergussmasse abgedichtet. Sie kann auch verwendet werden, um die Anwendung auf eine druckfeste Ex d-Barriere-Anwendung aufzurüsten. Verfügbare Werkstoffe: Messing, Messing vernickelt, Edelstahl 1.4404, V4A, 316L, Aluminium Zündschutzarten: Ex d IIC Gb, Ex e IIC Gb, Ex tb IIIC Db II 2 GD Einsetzbar in Zone 1, Zone 2, Zone 21, Zone 22 und in den Gasgruppen IIA, IIB and IIC. Explosionsschutz nach ATEX/IECEx NEC Protection: Class I Div 1 ABCD, Class II Div 2 EFG and Class III, Class I, Zone I, AEx db IIC Gb, AEx eb IIC Gb; Zone 21, AEx tb IIIC Db CEC Protection: Class I Div 1 ABCD, Class II Div 2 EFG and Class III Ex db IIC Gb; Ex eb IIC Gb; Ex tb IIIC Db Temperaturbereich: -60 °C / +80 °C Gewindearten: metrisch M20 bis M75, NPT 1/2" bis 3" Schutzart: IP66 Artikelnummer: CSB/656N
PERFECT AirVent Kabelverschraubung Kunststoff

PERFECT AirVent Kabelverschraubung Kunststoff

Die PERFECT AirVent Kabelverschraubung zum Schutz vor Kondenswasserbildung in hermetisch abgedichteten Elektro- und Elektronik-Gehäuse bei Temperatur- und Druckschwankungen. Eigenschaften: - konstante Be- und Entlüftung - Anpassung des Innendrucks - Wassereintrittspunkt für die Membran > 0,2 bar - in metrischen Größen M12, M16 und M20 - für Leitungen von 2 bis 13 mm - Temperaturbereich -20 °C / +100 °C (dynamisch) - Schutzart IP66 / IP68 PERFECT AirVent metric K348-1xxx-zz and K349-1xxx-zz K348-1xxx-zz Material: Polyamide PA6 Schutzart: IP66 / IP68 Für Kabeldurchmesser: 2-13 mm
PERFECT Kabelverschraubung Messing metrisch

PERFECT Kabelverschraubung Messing metrisch

Die PERFECT Kabelverschraubung aus vernickeltem Messing ist die passende Lösung zur Kabeldurchführung in verschiedensten industriellen Anwendungen. Eigenschaften: - integrierte Zugentlastung für Kabel und Leitungen - Verdrehschutz - großer Dicht- und Klemmbereich - für Leitungen von 3 bis 48 mm - montagefreundlich - Temperaturbereich-20 °C / +100 °C (dynamisch) -40 °C (statisch, kurzzeitig) - Schutzart IP68 - 5 bar / IP69K - Prüftzertifikate VDE / UL / DNV - viele Varianten und Zubehörteile verfügbar Artikelnummer: 50.6xx M Schutzart: IP68 - 5 bar, IP69K Für Kabeldurchmesser: 3-48 mm
PERFECT EMV-Kabelverschraubung Messing metrisch

PERFECT EMV-Kabelverschraubung Messing metrisch

Die PERFECT EMV-Kabelverschraubung aus vernickeltem Messing ist die passende Lösung zur Durchführung geschirmter Kabel und Leitungen zur Sicherung eines störungsfreien Betriebs von elektrischen Geräten und Anlagen. Eigenschaften: - schnelle und einfache EMV-Verbindung - integrierte Zugentlastung für Kabel und Leitungen - großer Dicht- und Klemmbereich - für Leitungen von 3 bis 48 mm - Temperaturbereich-20 °C / +100 °C (dynamisch) -40 °C (statisch, kurzzeitig) - Schutzart IP68 - 5 bar - Prüfnorm UL 514B PERFECT EMC metric 50.6xx M/EMVD, 50.6xx M/EMV 50.6xx M/EMVD, 50.6xx M/EMV Material: Messing vernickelt Schutzart: IP68 Für Kabeldurchmesser: 3-48 mm
Ex-Kabelverschraubungen für Anwendungen nach NEC/CEC/UL/CSA

Ex-Kabelverschraubungen für Anwendungen nach NEC/CEC/UL/CSA

HAWKE Ex-Kabelverschraubungen für Anwendungen nach NEC/CEC/UL/CSA Wir bieten eine große Auswahl an Kabelverschraubungen für Anwendungen mit speziellen amerikanischen Leitungen wie z.B. Metal Clad MC, Teck type, braid armoured marine shipboard jacketed, armoured jacketed oder non-jacketed Leitungen. Verfügbare Werkstoffe: Messing, Messing vernickelt, Edelstahl 1.4404, V4A, 316L, Aluminium Zündschutzarten: Ex d, Ex e, Ex tb, Ex nR, Ex tc Einsetzbar in Zone 1, Zone 2, Zone 21, Zone 22 und in den Gasgruppen IIA, IIB and IIC. Explosionsschutz nach Class 1, Division 1, Gas Groups ABCD Class 1, Division 2, Gas Groups ABCD Class 1, Zone 2, Gas Groups IIA, IIB, IIC Temperaturbereich: -50 °C / +60 °C (UL) -60 °C / +80 °C (ATEX / IECEx) Gewindearten: metrisch M16 bis M100, NPT 1/2" bis 4" Schutzarten: IP66, IP67, IP68 (30 Meter für 7 Tage), IP69, Deluge Protected DTS01, NEMA 4X Artikelnummer: HAWKE North American Ex-cable glands
BIRTFLEX 572 SY-JB

BIRTFLEX 572 SY-JB

PVC INSULATED, STEEL WIRE BRAID CONTROL CABLES These steel wire braided flexible connecting cables which core colours difference from each other are more used in mechanical engineering for instrumentation and control equipment for tooling machinery production lines and flexible applications for free movement without tensile load and dry, ambitient, wet places. The cores up to 1,0 mm2 service voltage is 300/500 V and 1.5 mm2 and after 2.5 mm2 cores service voltage 450/750 V. The armour above the inner sheath, steel wire braid serves as protection against mechanical traverse loads and act as a magnetic screen against interference. The galvanised steel wires are free of corresion and oxidation. These cables are not used for outdoor or underground installation. Conductor: Flexible copper wires, plain; IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: PVC compound , TI2 Core identification: Coloured cores Lay-up: Cores laid up in layers of optimum pitch Inner Sheath: PVC compound, RAL 7001,Grey Armour: Braid of galvanised steel wires, approx. %85 cove. Outer sheath: PVC compound, TM2 Sheath colour: RAL 7001,Grey or Transparent Standard: DIN VDE 0281-5 – VE 0281-13VDE 0245-102 (Designed according to) Insulation resistance: Min. 50 MΩ.km Rated voltage Uo/U: ≤ 1,0 mm2 : 300 / 500V, ≥ 1,5 mm2 : 450 / 750 V Test voltage: 4000 V Temperature range: Fixed: - 40 oC ~ + 70 oC; Mobile: - 5 oC ~ + 70 oC Min. bending radius: Fixed: 4 x D; Mobile: 12,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1
BIRTFLEX 552-H HSLH

BIRTFLEX 552-H HSLH

HALOGEN-FREE, FLEXIBLE CONTROL CABLES These halogen-free flexible connecting cables are more thinner and lighter than the other control cables and used in mechanical engineering for instrumentation and control equipment for tooling machinery production lines and flexible applications for free movement without tensile load and dry, ambitient, wet places. These cables are used at covered areas, plants and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. These cables are not used for outdoor or underground installation. Conductor: Flexible copper wires, plain;, IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: HFFR compound, TI6, TS/DIN EN 50367-7 Core identification: Acc. to TS/DIN EN 50334 black cores with, white numerals with green/yellow from 3 cores Lay-up: Cores laid up in layers of optimum pitch Outer sheath: HFFR compound, TM7, TS/DIN EN 50367-8, Halogen-free flame retardant, -OZ:Numbered cores black Sheath colour: RAL 7001,Grey Standard: TS HD 21.14 S1 & TS HD 21.13 S1, (Designed according to) Insulation resistance: Min. 20 MΩ.km Rated voltage: 300 / 500V Test voltage: 2000 V Temperature range: Fixed: - 30 oC ~ + 70 oC, Mobile: - 5 oC ~ + 50 oC Min. bending radius: Fixed: 6 x D, Mobile: 12,5 x D Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2 Flame test: IEC 60332-3 & TS/DIN EN 50266-2-4
BIRTFLEX 552-C / YSLCY

BIRTFLEX 552-C / YSLCY

PVC INSULATED, SCREENED CONTROL CABLES Conductor: Flexible copper wires, plain; , IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: PVC compound , TI2 Core identification: Acc. to TS/DIN EN 50334 black cores with white numerals with green/yellow from 3 cores Lay-up: Cores laid up in layers of optimum pitch Separator: Polyester tape Screen: Braid of tinned copper wires, 85% coverage Outer sheath: PVC compound, TM2 Sheath colour: RAL 7001, Grey Standard: TS HD 21.13 S1, DIN VDE 0281-13 VDE 0245-102 Insulation resistance: Min. 20 MΩ.km Rated voltage Uo/U: 300 / 500V Test voltage: 4000 V Temperature range: Fixed: - 40 oC ~ + 70 oC; Mobile: - 5 oC ~ + 70 oC Min. bending radius: Fixed: 4 x D; Mobile: 7,5 x D
BIRTFLEX-EF 659-PUR

BIRTFLEX-EF 659-PUR

PP INSULATED, PUR SHEATED EXTRA FLEXIBLE OIL RESISTANT CONTROL CABLES These oil, cold and extreme mechanical loads resistance high-flexibility PUR sheated control cables are designed for applications where cable high flexibility is needed. These type is more economical than BIRTFLEX-EF 6512. These cables with high service periods, are used for instrumention ,control and connecting of control units in mechanical tool construction, conveyor and assembly lines, production lines, any areas where continuous bending loads for free movement which has no pulling force ,with low tensile load forced movement in the cable trailing chain is required and at heavy conditions, dry, ambitient, cold and wet places. Conductor: Extra flexible copper wires, plain; IEC 60228 Class 6, TS/DIN EN 60228 Class 6 Insulation: PP compound, 9Y Core identification: Numbered cores or colour coded cores Lay-up: Cores laid up in layers of shorten optimum pitch Separator: Textile bandaging, at each lay-up layer. Outer sheath: PUR compound, 11YM1 Sheath colour: RAL 7001, Grey Standard: TS HD 21.13 S1, DIN VDE 0281-13DIN VDE 0282-10 (Designed according to) Insulation resistance: Min. 50 MΩ.km Rated voltage Uo/U: 300 / 500V Test voltage: 2000 V Temperature range: Fixed: - 30 oC ~ + 80 oC; Mobile: - 5 oC ~ + 70 oC Min. bending radius: Fixed: 4 x D; Mobile: 7,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1 Oil test: IEC 60811-2-1
Klappenhalter mit Seilzug LiftMini

Klappenhalter mit Seilzug LiftMini

Klappenhalter mit Seilzug LiftMini Horizontal-Vertikal einsetzbar Kunststoff grau 9206688 Klappenhalter mit Seilzug, 100N• Für Holzfronten oder Rahmenfronten aus Holz • Öffnungs- und Schließdämpfung• Klappengewicht inkl. Griff max. 1,4 - 14,5 kg• Klappenmaße: Höhe 200 - 480 mm• Zum Aufschrauben auf die Korpusseite, rechts / links verwendbar• horizontal und vertikal einsetzbar für besonders geringen Platzbedarf• Klappenbeschlag Kunststoff grau• Frontbefestigung Zinkdruckguss vernickelt• Abdeckkappe, bitte separat bestellen• Klappe muss unten mit Topfscharnieren oder Klappenscharnieren angeschlagen werden, bitte separat bestellen Set besteht aus:• 1 Stück Klappenbeschlag• 1 Stück Frontbefestigung für Holzfronten• Befestigungsmaterial (Euroschrauben für Klappenbeschlag und Frontbefestigung) Artikelnummer: E9206688 Gewicht: 0.331 kg
Klappenhalter mit Seilzug LiftMini

Klappenhalter mit Seilzug LiftMini

Klappenhalter mit Seilzug LiftMini Horizontal-Vertikal einsetzbar Kunststoff grau 9206691 Klappenhalter mit Seilzug, 200N• Für Holzfronten oder Rahmenfronten aus Holz • Öffnungs- und Schließdämpfung• Klappengewicht inkl. Griff max. 1,4 - 14,5 kg• Klappenmaße: Höhe 200 - 480 mm• Zum Aufschrauben auf die Korpusseite, rechts / links verwendbar• horizontal und vertikal einsetzbar für besonders geringen Platzbedarf• Klappenbeschlag Kunststoff grau• Frontbefestigung Zinkdruckguss vernickelt• Abdeckkappe, bitte separat bestellen• Klappe muss unten mit Topfscharnieren oder Klappenscharnieren angeschlagen werden, bitte separat bestellen Set besteht aus:• 1 Stück Klappenbeschlag• 1 Stück Frontbefestigung für Holzfronten• Befestigungsmaterial (Euroschrauben für Klappenbeschlag und Frontbefestigung) Artikelnummer: E9206691 Gewicht: 0.338 kg
Klappenhalter mit Seilzug LiftMini

Klappenhalter mit Seilzug LiftMini

Klappenhalter mit Seilzug LiftMini Horizontal-Vertikal einsetzbar Kunststoff grau 9206677 Klappenhalter mit Seilzug, 60N• Für Holzfronten oder Rahmenfronten aus Holz • Öffnungs- und Schließdämpfung• Klappengewicht inkl. Griff max. 1,4 - 14,5 kg• Klappenmaße: Höhe 200 - 480 mm• Zum Aufschrauben auf die Korpusseite, rechts / links verwendbar• horizontal und vertikal einsetzbar für besonders geringen Platzbedarf• Klappenbeschlag Kunststoff grau• Frontbefestigung Zinkdruckguss vernickelt• Abdeckkappe, bitte separat bestellen• Klappe muss unten mit Topfscharnieren oder Klappenscharnieren angeschlagen werden, bitte separat bestellen Set besteht aus:• 1 Stück Klappenbeschlag• 1 Stück Frontbefestigung für Holzfronten• Befestigungsmaterial (Euroschrauben für Klappenbeschlag und Frontbefestigung) Artikelnummer: E9206677 Gewicht: 0.329 kg