Finden Sie schnell kabel konfektionieren online für Ihr Unternehmen: 320 Ergebnisse

RE-Y(St)Y-fl

RE-Y(St)Y-fl

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 1MULTİ-CORE, PVC INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: Up to 40 cores; yellow with black numbers and, word printed (1-40), (10,TEN); up to 80 cores;, black with yellow numbers and word printed, (1-40), (10,TEN) Lay-up: Cores laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 1 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,0 Ω/km, 0,75mm2 : 26,0 Ω/km, 1,5mm2 : 12,1 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
PUR-Kabel für die Automation

PUR-Kabel für die Automation

PUR-Kabel für die Automation: Anlagenbau, Sondermaschinenbau, Chemieindustrie. Im Bereich der Automation sowie Sensorik ist eine schnelle Datenübertragung eine der Grundanforderungen für Kabel und Leitungen. Schließlich müssen Steuerungsbefehle oder Messdaten völlig verzögerungsfrei zwischen den verschiedenen Ebenen einer Automatisierungs- oder einer Mess- und Regeltechnik ausgetauscht werden. Insbesondere bei der industriellen Automation können gleichzeitig hohe mechanische Belastungen auf Kabeltrassen und Leitungen einwirken. Wir erstellen entsprechend Ihrer Anforderungen exakt die passende Kabellösung. Ob Sie Leitungssysteme für die reine Datenübertragung benötigen, oder zugleich die energetische Versorgung über das gleiche Kabel sicherstellen müssen. Ob Sie eine feste Verlegung benötigen oder diese im flexiblen Dauereinsatz ist, unsere modularen Kombinationsmöglichkeiten erlauben es uns, nahezu jedes Problem in der Automation zu lösen. Dabei zeichnen sich unsere Produkte durch absolute Langlebigkeit und Zuverlässigkeit aus.
PUR-Kabel für den Aufzugbau

PUR-Kabel für den Aufzugbau

PUR-Kabel für den Aufzugbau: Personenaufzüge, Lastenaufzüge, Panoramaaufzüge. Im Bereich des Aufzugbaus und der Lifttechnik müssen für die Sicherheit der zu befördernden Personen und für die Zuverlässigkeit der Fördertechnik einige grundlegende Anforderungen erfüllt sein. Zum einen müssen die verwendeten Kabel starken mechanischen Belastungen standhalten. So sollten sie eine hohe Biegewechselfestigkeit aufweisen, denn gerade beim Einsatz in beispielsweise Bürogebäuden sind mehrere hunderte Fahrten pro Tag keine Seltenheit. Das bedeutet eine Dauerbelastung auch für die Kabeltechnik – und das über Jahre hinweg. Daher müssen die eingesetzten Kabel robust und verschleißfrei sein. Weiterhin: Hohe Anforderungen in Punkto Personensicherheit. Eine maßgebliche Rolle spielt hier u.a. der bauliche Brandschutz, die Auflagen sind hinsichtlich der zulässigen Materialien besonders streng. Zum anderen bedeutet das sichere Verkabeln von Fahrstühlen natürlich weit mehr, als nur die energetische Versorgung unter Einhaltung des Brandschutzes sicherzustellen.
XtraBASIC-plus

XtraBASIC-plus

XtraBASIC-plus - entwickelt für den exportorientierten Anlagen- und Maschinenbauer. Zur Verdrahtung von Schaltschränken, als Verbindungsleitung v. Maschinen und als Anschlussleitung für Motoren. XtraBASIC-plus - entwickelt für den exportorientierten Anlagen- und Maschinenbauer. Die Leitung eignet sich zur Verdrahtung von Schaltschränken, für Installationstechnik und Geräte, als Verbindungsleitung von Maschinen und als Anschlussleitung für Motoren und Transformatoren.
RE-Y(St)YSWAY-fl

RE-Y(St)YSWAY-fl

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 2MULTİ-CORE, PVC INSULATED, COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: Up to 40 cores; yellow with black numbers and, word printed (1-40), (10,TEN); up to 80 cores;, black with yellow numbers and word printed, (1-40), (10,TEN) Lay-up: Cores laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PVC compund, TM1, BS 7655, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 2 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,0 Ω/km, 0,75mm2 : 26,0 Ω/km, 1,5mm2 : 12,1 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
Magnetische Steckverbinder auf Federkontaktbasis

Magnetische Steckverbinder auf Federkontaktbasis

Wir konstruieren und fertigen magnetische Steckverbinder auf Federkontaktbasis inkl. der passenden Kabelkonfektionierung Der Stecker besteht aus Federkontaktstiften und einem magnetischen Verbindungssystem. Die Implementierung eines Magneten sorgt für eine schnelle schock- und vibrationsbeständige, sowie selbstführende Verbindung bzw. einfache Lösung von Stecker und Gerät. Durch die Federkontakte können nicht nur Ladestrom, sondern auch alle andere Arten von Signalen übertragen werden. Die Kontaktpunkte werden im Gerät mit der Platine verlötet. Vorteil dieser Technik ist die hohe Funktionssicherheit bei einer sehr hohen Zyklenanzahl von mindestens 10.000 Wiederbefestigungen. Eine kundenspezifische Entwicklung bietet sich, bedingt durch die Erstellung von Werkzeugen, bereits ab einer Produktionsmenge von 5.000 Stück an. Gerne unterstützen wir Sie bei der Entwicklung und Konstruktion einer passenden magnetischen Stecklösung für ihr System. Bitte senden Sie uns einfach eine Email mit den geforderten Spezifikationen und einer evtl. bereits vorhandene Zeichnung. Unser spezialisiertes Ingenieursteam wird sich umgehend mit Ihnen in Verbindung setzen.
Kabelkonfektionierung

Kabelkonfektionierung

Wir konfektionieren nach Kundenvorgabe, jegliche Art von elektronischen Kabeln und Bauteilen. Stromversorgungskabel, LED-Lichtbänder, Komponentenverbindungen inklusive Funktionsprüfung
SAS Kabel intern SFF-8484 auf SFF-8484

SAS Kabel intern SFF-8484 auf SFF-8484

- 32-pol. SAS Stecker SFF-8484 auf 32-pol. SAS Stecker SFF-8484 - Datenkabel zum Anschluss von SAS Laufwerken - 4c Multilane Host to Target Cable
GN 330 Kabel mit Anschlusskupplung

GN 330 Kabel mit Anschlusskupplung

Kabel mit Anschlusskupplung GN 330 werden in Verbindung mit Normelementen verwendet, die eine elektrische Schaltfunktion haben. EAN: 4045525578036 Artikelnummer: 330-M12X1-12-W-5 Anschlusskupplung: M 12 x 1 Anzahl der Kontakte (Form G/W): 12, 12 Kabellänge L1 (In Meter) L1: 5 ROHS: Ja
Kabelkonfektion (Wiring harness) von individuellen Einzelleitungen und komplexen Kabelbäume

Kabelkonfektion (Wiring harness) von individuellen Einzelleitungen und komplexen Kabelbäume

Kabelkonfektion: Bei unserer Fertigung haben wir langjährige Erfahrung mit Kabelarten und Bauteilen aller namhaften Hersteller weltweit. Individuellen Einzelleitungen und komplexen Kabelbäume. Kabelkonfektion / Wiring harness Bei unserer Fertigung haben wir langjährige Erfahrung mit Kabelarten und Bauteilen aller namhaften Hersteller weltweit. We provide many years of experience with a variety of cable types and other components from many well-known suppliers worldwide.
Kabelsätze und Kabelbäume konfektioniert

Kabelsätze und Kabelbäume konfektioniert

Konfektion von Kabelsätzen und Kabelbäumen im Querschnittsbereich 0,14 mm² - 240 mm². Kabelkonfektion von Kabelsätzen und Kabelbäumen im Querschnittbereich 0,14 mm² bis 240 mm² Querschnitt, größere Querschnitte auf Anfrage.
BayCom® A-DQ2Y(ZN)2Y

BayCom® A-DQ2Y(ZN)2Y

Selbsttragendes, metallfreies LWL-Luftkabel ADSS (All-Dielectric Self-Supporting), als Anschluss- und Verbindungskabel in Weitverkehrs- und Ortsnetzen, in Nebenstellenanlagen, zum Fernsprechen und zur Übertragung von Daten. Das Kabel ist geeignet zur Verlegung an Masten, Ober- oder Freileitungen, zwischen Gebäuden oder anderen Anwendungsfällen mit erhöhten Anforderungen an die Zug- oder Schwingungsbelastbarkeit für eine Spannweite bis zu 100m. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
Kabelbäume und Kabelkonfektion

Kabelbäume und Kabelkonfektion

Kabel übertragen Energie oder Signale an Anwendungsgeräte – in der Elektrotechnik, Medizintechnik oder Automobiltechnik. Dabei hat jedes Kabel je nach Aufgabenbereich seine individuellen Anforderungen. Wenn es um die Herstellung von präzisen Daten- und Kommunikationsleitungen, geschirmten und ungeschirmten Kabeln, Kabelbäumen, mehradrigen Spezialkabeln oder Rund- und Flachlitzen geht, ist fachmännisch exaktes Handwerk gefragt. Im medizintechnischen Bereich verarbeiten wir bei der Konfektionierung darüber hinaus Steckverbindungssysteme wie Multikupplung, Schnellkupplung oder Magnetventilkupplung.
BaySpecial®  NAKBY  3,6/6 kV  3-adrig

BaySpecial® NAKBY 3,6/6 kV 3-adrig

Massekabel/Gürtelkabel für die Verlegung in Erde, im Freien, in Innenräumen und Kabelkanälen. Insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze. In Erde, im Freien, in Innenräumen und Kabelkanälen, wenn keine besonderen mechanischen Beanspruchungen zu erwarten sind (siehe DIN VDE 0298-1). Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
Konfektionen Einzelader

Konfektionen Einzelader

Litzen und Leitungen werden in unterschiedlichen Längen geschnitten und verarbeitet. Halbautomatische Crimpung und/oder Vollautomatische Verarbeitung an Komax Stripper/crimpern. Voll- oder Halbautomatisch werden Kabelschuhe, wie Ringe, Flachsteckhülsen, Aderendclip, Kontaktfedern und Buchsen, gedrehte Kontakte uvm. mit elektrischer Crimpüberwachung angebracht. Isolationen der Kabelschuhe mit Schrumpfschlauch, Tüllen oder bereits als fertiges Produkt kommen zum Einsatz. Kabel- und Adermarkierung im Thermotransferverfahren werden angeboten.
Kabelkonfektionierung

Kabelkonfektionierung

Vielfältiges Leistungsangebot an Kabelbäumen. Diese besitzen eine große Vielfalt an unterschiedlichen Leitungs- und Steckertypen und sind 100%ig getestet, hochspannungsgeprüft somit einbaufertig. Dazu gehören Kabelbäume und -verteilungen, vorgefertigt, geprüft und mit Garantie. Hierbei greifen wir auf die unterschiedlichsten Löt,- Crimp- und Schneidklemmtechniken zurück. Wir fertigen nach Ihren Wünschen in jeder Anschlusstechnik und in jeder Ausführung.
Kabel mit Tragorganen für den Aufzugbau

Kabel mit Tragorganen für den Aufzugbau

Kabel mit Tragorganen (außen- und innenliegend) für den Aufzugbau: Personenaufzüge, Lastenaufzüge, Panoramaaufzüge. Im Bereich des Aufzugbaus und der Lifttechnik müssen für die Sicherheit der zu befördernden Personen und für die Zuverlässigkeit der Fördertechnik einige grundlegende Anforderungen erfüllt sein. Zum einen müssen die verwendeten Kabel starken mechanischen Belastungen standhalten. So sollten sie eine hohe Biegewechselfestigkeit aufweisen, denn gerade beim Einsatz in beispielsweise Bürogebäuden sind mehrere hunderte Fahrten pro Tag keine Seltenheit. Das bedeutet eine Dauerbelastung auch für die Kabeltechnik – und das über Jahre hinweg. Daher müssen die eingesetzten Kabel robust und verschleißfrei sein. Weiterhin: Hohe Anforderungen in Punkto Personensicherheit. Eine maßgebliche Rolle spielt hier u.a. der bauliche Brandschutz, die Auflagen sind hinsichtlich der zulässigen Materialien besonders streng. Zum anderen bedeutet das sichere Verkabeln von Fahrstühlen natürlich weit mehr, als nur die energetische Versorgung unter Einhaltung des Brandschutzes sicherzustellen.
RE-2Y(St)2YSWAY-fl-TIMF

RE-2Y(St)2YSWAY-fl-TIMF

INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , ,0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type 03 Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Two conductors twisted to a pair TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
KABELKONFEKTIONIERUNG

KABELKONFEKTIONIERUNG

Wir fertigen für unsere Kunden komplette Kabelsätze und -bäume mit einer Länge von bis zu 150 Metern. Solche Systemkabel kommen zum Beispiel bei Windkraftanlagen, Kränen oder großen Gebäuden zum Einsatz. Je nach Kundenwunsch sind die Kabelkonfektionen mit Endhülsen oder Steckern in allen Variationen ausgestattet. Länge, Leitungsquerschnitte, Anbauteile, Beschriftung und die Art der Qualitätsprüfung ermitteln wir mit Ihnen im persönlichen Gespräch.
Ölbeständiges Kabel

Ölbeständiges Kabel

Es ist geeignet für den Einsatz an Werkzeugmaschinen, Steuergeräten und Fließ- und Montagebändern. Anwendungsbereich : Dieses Tray Cable und Maschine-Tool Cable ist UV- und ölbeständig und zudem auch noch flexibel. Es ist geeignet für den Einsatz an Werkzeugmaschinen, Steuergeräten und Fließ- und Montagebändern. Produktvorteile : - Flexible Leitungen für den Einsatz als Tray Cable - ölbeständig - UV-Beständig - NFPA 79 für Industrieanlagen - WTTC Zulassung - WTTC: UL Subject 2277 - TC: UL Standard 1277 - (UL)/(cUL) approbiert
BayEnergy® N2XCWY  0,6/1 kV  3-adrig

BayEnergy® N2XCWY 0,6/1 kV 3-adrig

Starkstromkabel für höhere Leitertemperaturen zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur und eine höhere Belastbarkeit im Kurzschlussfall als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
SIMH-FR/PF FE 180

SIMH-FR/PF FE 180

HIGH TEMPERATURE, TWISTED PAIR RESISTANT TO FIRE SILICONE CABLES These twisted pairs (pair form) cables fields of use as a control and power supply cable they are fire proof and halogen free cables which, on the basis of a fixed operating mode, can continue with the supply of a power for a period of 180 minutes under the existing fire conditions (at a temperature of 750OC and under the flames ). Also these cables shall satify EN50200 test which is a fire resistant with mechancal shock test (under the conditions at 842oC and mechenical shock) by the classes PH15-PH30-PH60-PH90, if it has requsted, Because of their unique features, they can be used; on the fire alarm systems, lighting systems on the equipment and devices which are connected to the fire alarm devices, in the environments which have no corrosive gases are emitted in the event of fire. These cables are used at metro, schools, airpots, hospitals, etc. Conductor: IEC 60228 Class 5, TS/DIN EN 60228 Class 5, Flexible copper wires, plain; Insulation: Speacial silicone rubber compound Core identification: According to TS HD 308 S2 & VDE 0293-308, Acc. to TS/DIN EN 50334 black cores with, white numerals with green/yellow after 5 cores Lay-up: Cores laid up in layers of optimum pitch Outer sheath: Silicone rubber compound Sheath colour: RAL 2009, Orange Standard: VDE 0250, DIN VDE 0282-15 and, TS HD 22.15 S1, (Designed according to) Insulation resistance: Min. 20 MΩ.km Temp. at conductor: + 180 oC Short circuit tempetarure: +200oC Rated voltage: 300 / 500V Test voltage: 2000 V Temperature range: Fixed: - 60 oC ~ + 180 oC, Mobile: - 25 oC ~ + 180 oC Min. bending radius: Fixed: 4 x D, Mobile: 7,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1, IEC 60332-3 & EN 50266-2-4 Insulation integrity: IEC 60331 , VDE 0472-814 Fire resistant with mechanical shock*Upon request: DIN EN 50200 ; PH 15 (15 minutes), DIN EN 50200 ; PH 30 (30 minutes), DIN EN 50200 ; PH 60 (60 minutes), DIN EN 50200 ; PH 90 (90 minutes)
RE-2Y(St)Y-fl

RE-2Y(St)Y-fl

INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1SİNGLE & MULTİ-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , ,0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type03 Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…) Triple: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
RE-Y(St)YSWAY-fl-MP

RE-Y(St)YSWAY-fl-MP

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 1SİNGLE & MULTİ-PAİR, PVC INSULATED, COLLECTİVE SCREENED,ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: According to BS 5308 Part 2 colour coded, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PVC compund, TM1, BS 7655, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 2 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
SCSI Kabel - LVD/U320 intern

SCSI Kabel - LVD/U320 intern

Low Voltage Differential SCSI Buskabel: - 160 MB/s bei Ultra160 bzw. 320MB/s bei Ultra320 LVD SCSI Kabel - Amphenol Spectra Strip: - SCSI Flachbandkabel beidseitig stabil laminiert LVD SCSI Kabel - Round/Airflow: - hochflexibles Madison U160/U320 scsi cable - Abstände innerhalb der Spezifikation frei wählbar - Lagenverseilung (TPWR-/REC-/ACK-Leitungen haben definierte Lage) Steckverbinder: - Stiftstecker HalfPitch 1,27 mm; IDC; UL - Buchsenstecker: HP 1,27 mm; IDC; UL Panelmount Screw/Clip
Klemmbügel

Klemmbügel

Stahl = St3 K 50 GBK nach DIN 1624 Messing = CuZn37 F55 nach DIN 17670 Die Klemmbügel werden generell in Stahl verzinkt oder Messing vernickelt geliefert; andere galvanische Überzüge aus Wunsch. Ausführung nach DIN 50960: für St: vz - gal Zn 5 bke; vk - gal Cd 5 bke für Ms: vn - gal Ni 5 bk Bezeichnung eines Klemmbügels Form E der Nenngröße aus CuZn37 F55 (Ms) vernickelt (vn): Klemmbügel E3 DIN 46282 - Ms vn
Kundenspezifische Kabelkonfektion und Elektronikfertigung für Automotive, Industrie...

Kundenspezifische Kabelkonfektion und Elektronikfertigung für Automotive, Industrie...

Wir sind spezialisiert auf die Entwicklung und Fertigung individueller Lösungen für Anbindungen der peripheren Infrastruktur mit intelligenten Kabelkonfektionen und Elektronikbaugruppen Hohe Beratungskompetenz und unsere Leidenschaft für zukunftsweisende Technik und unser hochmotiviertes Team aus Ingenieuren & Entwicklern stehen zur Verfügung, um Ihnen passgenaue Lösungen im Bereich Product Engineering zu liefern – unter Berücksichtigung technischer, ökonomischer und logistischer Aspekte. Dabei bieten wir Ihnen die Projektabwicklung bis hin zur kompletten Lohn- bzw. Auftragsfertigung an. Lesen Sie hier dazu mehr.
Spritztechnik

Spritztechnik

Zugentlastung/Gehäuseeinführungen Lassen Sie die teuren konventionellen Kabeleinführungen mit Verschraubungen, Dichtringen und Gegenmutter hinter sich. Nutzen Sie unsere einfachen und preiswerten angespritzten Kabeleinführungen mit Zugentlastung. Stecker/Steckverbinder Mit unsrer Vertikalspritzmaschine fertigen für Sie individuelle Steckverbinder nach Ihren Vorgaben oder Wünschen. Einlegeteile / Umspritzungen Mit unserer Vertikal-Spritzgießmaschine umspritzen wir Ihre Einlegeteile z.B. aus Kunststoff, Metall oder Feritte nach Ihren Anforderungen.
XtraBASIC-mini

XtraBASIC-mini

XtraBASIC-mini - entwickelt für den exportorientierten Anlagen- und Maschinenbauer. Zur Verdrahtung von Schaltschränken, als Verbindungsleitung v. Maschinen und als Anschlussleitung für Motoren. XtraBASIC-mini - entwickelt für den exportorientierten Anlagen- und Maschinenbauer. Die Leitung eignet sich zur Verdrahtung von Schaltschränken, für Installationstechnik und Geräte, als Verbindungsleitung von Maschinen und als Anschlussleitung für Motoren und Transformatoren.
Ultraschallschweißen

Ultraschallschweißen

Das Ultraschall-Litzenschweißen/Verdichten ermöglicht es, Ader-Querschnitte (bis 35mm²) zu kompaktieren oder Spleiß- und Knotenpunkte in Kabelsätzen zu erstellen. Im Zuge einer fortschreitenden Miniaturisierung wird mit einer Reduktion auf den eigentlichen Querschnitt der Litzen durch Ultraschallverdichtung eine höhere Flexibilität erreicht. Ein weiterer Vorteil liegt in der Möglichkeit der Knotenbildung, also einer Verschweißung mehrer, auch unterschiedlich starker Litzen, wo sonst Kabelschuhe verschiedenster Ausführung kombiniert werden müssten. Alle Kupferlitzen blank können für diese Verfahrenstechnik eingesetzt werden. Der zu verarbeitende Querschnittsbereich liegt bei 0,5mm² bis zu 35mm².