Finden Sie schnell kabel vorkonfektioniert für Ihr Unternehmen: 1022 Ergebnisse

Steuerleitung konfektioniert

Steuerleitung konfektioniert

Kabelring mit Konfektion an beiden Enden. Gewicht: ca. 1kg
RE-2Y(St)2YSWAY-fl-TIMF

RE-2Y(St)2YSWAY-fl-TIMF

INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , ,0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type 03 Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Two conductors twisted to a pair TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PE compound, BS 6234 Type 03, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
Kabelsätze, konfektionierte

Kabelsätze, konfektionierte

Wenn wir von Kabelkonfektion sprechen, meinen wir damit die gesamte Prozesskette für ein Outsourcing, das Ihnen einen Mehrwert erschließt. Kabelkonfektion vom Fachbetrieb In der Kabelkonfektionierung bzw. Kabelkonfektion bieten wir mehr als herkömmliche Kabel-Konfektions-Betriebe, die sich nur auf die Fertigung von anschlussfertigen Kabel-Lösungen mit Steckverbindern oder Kontaktierungen bzw. Ader-Endhülsen spezialisiert haben. Bei SAREK KABEL geht es nicht nur um das "Strippenziehen", sondern die Lieferung der für Sie optimalen Lösung in der für Sie kostengünstigsten Variante mit der für Sie effizientesten Prozesskette. Dieses Denken in Lösungen und in Prozessen zeichnet uns aus. Wir haben nicht nur die Kabelkonfektion, sondern die für Sie beste wirtschaftliche Komponente mit im Blick. In der Verarbeitung kommen bei uns viele Techniken zum Einsatz, nicht nur die traditionellen Crimp- und Löttechniken. Kabelkonfektion für alle Branchen SAREK KABEL bietet Kabelkonfektion für alle Branchen, ob Kabelkonfektion von Spezialkabeln und Sonderleitungen Kabelkonfektion von Medizinkabeln Kabellösungen für Automotive Konfektionierte Kabel für die Industrie Hochtemperaturbeständige konfektionierte Kabel Konfektionierte Miniaturkabel Kabelkonfektionierer von Sensorkabeln Kabel für Energiemaschinen Kabel für die Mess- & Regeltechnik Robotik-Kabel und vieles mehr
Kabel mit Tragorganen für den Aufzugbau

Kabel mit Tragorganen für den Aufzugbau

Kabel mit Tragorganen (außen- und innenliegend) für den Aufzugbau: Personenaufzüge, Lastenaufzüge, Panoramaaufzüge. Im Bereich des Aufzugbaus und der Lifttechnik müssen für die Sicherheit der zu befördernden Personen und für die Zuverlässigkeit der Fördertechnik einige grundlegende Anforderungen erfüllt sein. Zum einen müssen die verwendeten Kabel starken mechanischen Belastungen standhalten. So sollten sie eine hohe Biegewechselfestigkeit aufweisen, denn gerade beim Einsatz in beispielsweise Bürogebäuden sind mehrere hunderte Fahrten pro Tag keine Seltenheit. Das bedeutet eine Dauerbelastung auch für die Kabeltechnik – und das über Jahre hinweg. Daher müssen die eingesetzten Kabel robust und verschleißfrei sein. Weiterhin: Hohe Anforderungen in Punkto Personensicherheit. Eine maßgebliche Rolle spielt hier u.a. der bauliche Brandschutz, die Auflagen sind hinsichtlich der zulässigen Materialien besonders streng. Zum anderen bedeutet das sichere Verkabeln von Fahrstühlen natürlich weit mehr, als nur die energetische Versorgung unter Einhaltung des Brandschutzes sicherzustellen.
Kabel und Kabelbäume

Kabel und Kabelbäume

Zusätzlich zu seinen Spitzenleistungen auf dem Gebiet der Elektronikmontage in den europäischen Werken, verfügt Incap Slowakei über eine bewährte Produktionsanlage für Kabel und Kabelbäume Das umfangreiche Angebot reicht von einfachen HF-Kabelkonfektionen bis hin zu komplizierten, mehradrigen Datenkabeln, die entsprechend der Richtlinien des Verteidigungssektors gefertigt werden AWS ist Spezialist für Prototyping und Fertigung kleiner bis mittlerer Serien von hoher Vielfalt und Komplexität. Durchweg wird die Leistungsklasse 3 von IPC 610 und IPC 620 eingehalten. Funktionstest, Rückverfolgbarkeit und Dokumentation werden je nach Wunsch des Kunden geboten. Die Anlagen umfassen: Automatisches Zuschneiden und Abmanteln von Kabeln Pneumatisches Bündeln und Crimpen Etikettieren und Kennzeichnungsbedruckung Automatische Prüfeinrichtung: Wechsel- und Gleichspannung, Spannungs- und Durchschlagsfestigkeit, Stromdurchgang und Kurzschluss Sicherheitsprüfgeräte Vor- und Umformen Zusätzliche Dienste umfassen: Design und Spezifikation von Kabeln Planung der Kabelverlegung Unterstützende Beratung für Kabel und Verbinder Vermeidung von Störungen, Kreuzkopplungen und Interferenzen Verdrahtung von Schaltschränken und Racks Unterstützung bei Installation und Inbetriebnahme Reparaturen am Einsatzort oder außerhalb Aufarbeitungs- und Modernisierungsdienste Reaktionsfähigkeit bei dringenden Anforderungen AWS betreibt ein umfassendes ERP/MRP-System und kann die Beschaffung komplett oder teilweise übernehmen oder auf Basis von Bereitstellung. Unsere Kunden profitieren von einem engagierten Vertragsteam, kompetenter Betreuung und kurzen Kommunikationswegen direkt zur Einsatzstelle.
BayEnergy®  NYY-O  0,6/1 kV  4-5-adrig

BayEnergy® NYY-O 0,6/1 kV 4-5-adrig

Starkstromkabel für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist (siehe DIN VDE 0298-1). Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist (siehe DIN VDE 0298-1). Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
BaySpecial®  NYKY-J  0,6/1 kV  3 ¹/₂ - 4 ¹/₂

BaySpecial® NYKY-J 0,6/1 kV 3 ¹/₂ - 4 ¹/₂

Bleimantelkabel speziell für Anlagen, bei denen mit der Einwirkung von Lösungsmitteln, Treibstoffen, Ölen, Benzin oder dergleichen gerechnet werden muss (z.B. in Tankstellen). Im Außenbereich, im Erdreich, speziell in Anlagen, wenn mit der Einwirkung von Lösungsmitteln, Treibstoffen, Ölen, Benzin oder dergleichen gerechnet werden muss (z. B. in Raffinerien oder Tankstellen). Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Aufgrund des flammwidrigen Mantels könnte es in die Brandklasse Eca eingestuft werden.
BayEnergy® (N)2X(L)2Y  0,6/1 kV  3-adrig

BayEnergy® (N)2X(L)2Y 0,6/1 kV 3-adrig

Querwasserdichtes Starkstromkabel für höhere Leitertemperaturen mit widerstandsfähigem HDPE-Außenmantel zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur und eine höhere Belastbarkeit im Kurzschlussfall als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind halogenfrei, UV-beständig und durch den Schichtenmantel querwasserdicht. Das Kabel ist für Verlegung im Erdreich oder außerhalb Bauwerken vorgesehen und unterliegt damit nicht der Bauproduktenverordnung. Es kann auch nicht in die Brandklasse Eca oder besser eingestuft werden.
Kabelkonfektionierung

Kabelkonfektionierung

Vielfältiges Leistungsangebot an Kabelbäumen. Diese besitzen eine große Vielfalt an unterschiedlichen Leitungs- und Steckertypen und sind 100%ig getestet, hochspannungsgeprüft somit einbaufertig. Dazu gehören Kabelbäume und -verteilungen, vorgefertigt, geprüft und mit Garantie. Hierbei greifen wir auf die unterschiedlichsten Löt,- Crimp- und Schneidklemmtechniken zurück. Wir fertigen nach Ihren Wünschen in jeder Anschlusstechnik und in jeder Ausführung.
Kabel für hohe Torsions- und Zugbeanspruchung, Robotik

Kabel für hohe Torsions- und Zugbeanspruchung, Robotik

Kabel für hohe Torsions- und Zugbeanspruchung, Robotik: Schweißroboter, Tauchroboter, Industrieroboter. Je nach Einsatzbereich und Funktion eines Roboters, muss die Verkabelung unterschiedlichste Anforderungen erfüllen. So müssen Kabel und Leitungen für Industrieroboter in der Regel starken mechanischen Beanspruchungen durch permanent gleiche Bewegungsabläufe standhalten. Bei Robotern für beispielsweise Schweiß- oder Unterwasserarbeiten sind zusätzliche Eigenschaften wie Hitzeresistenz oder absolute Wasserdichtheit gefordert. Je nachdem, wie viele Funktionalitäten ein Roboter haben soll, fällt auch der Leitungsumfang aus. So individuell, wie die Anforderungen hier sind, gibt es keine Lösungen von der Stange. Für die Robotik müssen Kabel und Leitungen grundsätzlich individuell, anwendungsbezogen und bedarfsgerecht konzipiert und entwickelt werden. Daher ermitteln unsere erfahrenen Experten vor der eigentlichen Realisierung gemeinsam mit Ihnen alle Anforderungen, Einsatzbedingungen und gegebenenfalls Sonderwünsche.
RE-2Y(St)YQY-fl

RE-2Y(St)YQY-fl

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, STEEL WIRE BRAIDED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the sheath, steel wire braid serves as protection against mechanical traverse loads and act as a magnetic screen against interference. The galvanised steel wires are free of corresion and oxidation.These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: PVC compound, EN 50290-2-22 Armour: Braid of galvanized steel wires, aprx. %85 cov. Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
Duplex-Breakoutkabel-Konfektion

Duplex-Breakoutkabel-Konfektion

Standards hergestellt und eignen sich hervorragend für die Verbindung von Geräten in rechenzentren, LANs, WANs und anderen Netzwerkanwendungen. Unsere Duplex-Breakout-Patchkabel sind mit hochwertigen Multimode- oder Singlemode-Fasern ausgestattet, die eine hohe Signalqualität und Übertragungsgeschwindigkeiten gewährleisten. Sie sind in verschiedenen Längen erhältlich und können flexibel an die Anforderungen Ihres Netzwerks angepasst werden. Die robuste Konstruktion der Kabel bietet eine zuverlässige Leistung und eine lange Lebensdauer. Die Stecker sind präzise gefertigt und sorgen für eine perfekte Passform und geringe Dämpfung. Dank ihrer niedrigen Einfügedämpfung und Rückflussdämpfung sind unsere Duplex-Breakout- Patchkabel ideal für High-Speed-Datenübertragungen geeignet. Darüber hinaus sind unsere Duplex-Breakout-Patchkabel einfach zu installieren und wartungsfrei. Sie sind mit LC-, SC-, ST- oder FC-Steckern erhältlich, um eine optimale Kompatibilität mit Ihren vorhandenen Geräten zu gewährleisten. Vertrauen Sie auf unsere Erfahrung und Qualität. Bestellen Sie noch heute Ihre Duplex-Breakout- Patchkabel und profitieren Sie von einer zuverlässigen und leistungsstarken Netzwerklösung.
3 in 1 Ladekabel REFLECTS-MONTIJA

3 in 1 Ladekabel REFLECTS-MONTIJA

Ein 3in1-Ladekabel mit Anschlüssen für Apple® und Android™ und alle Micro-USB-Geräte sowie USB-C. Auf dem Aluminiumgehäuse wirken Logos mit einer Lasergravur besonders hochwertig. Android ist eine Marke von Google Inc. Apple is a registered trademark of Apple Inc. Registered in the US and other countries Aluminium, silber, Polybeutel, USB 2.0, USB Typ C Artikelnummer: 1336403 Druckbereich: 14 x 23 Zolltarifnummer: 85444290 Gewicht: 20,4 g
LWL Patchkabel

LWL Patchkabel

Patchkabel sind wesentliche Komponenten in jedem Netzwerk, die für die Verbindung von Geräten innerhalb eines Netzwerks verwendet werden. Diese Kabel sind in verschiedenen Längen und Konfigurationen erhältlich, um den spezifischen Anforderungen jedes Netzwerks gerecht zu werden. Unsere Patchkabel sind von höchster Qualität und bieten eine zuverlässige und schnelle Datenübertragung. Sie sind ideal für den Einsatz in Rechenzentren, Büros und anderen Umgebungen, in denen eine stabile Netzwerkverbindung erforderlich ist. Durch die Investition in hochwertige Patchkabel können Unternehmen die Leistung und Zuverlässigkeit ihrer Netzwerke verbessern und gleichzeitig die Betriebskosten senken. Wir sind Ihr kompetenter Ansprechpartner für: Glasfaser-Installationen Netzwerktechnik Datenverbindungen Glasfaser-Spleißen Kupferverkabelung Netzwerkzertifizierung Multimode-Glasfaser Singlemode-Glasfaser EDV-Lösungen Netzwerkplanung Netzwerkberatung Inhaus-Datennetze LWL-Spleißen OTDR-Messungen Systemgarantie Netzwerkkomponenten Netzwerkmodernisierung Netzwerkservice Glasfasertechnik Netzwerkinstallation
Ölbeständiges Kabel

Ölbeständiges Kabel

Es ist geeignet für den Einsatz an Werkzeugmaschinen, Steuergeräten und Fließ- und Montagebändern. Anwendungsbereich : Dieses Tray Cable und Maschine-Tool Cable ist UV- und ölbeständig und zudem auch noch flexibel. Es ist geeignet für den Einsatz an Werkzeugmaschinen, Steuergeräten und Fließ- und Montagebändern. Produktvorteile : - Flexible Leitungen für den Einsatz als Tray Cable - ölbeständig - UV-Beständig - NFPA 79 für Industrieanlagen - WTTC Zulassung - WTTC: UL Subject 2277 - TC: UL Standard 1277 - (UL)/(cUL) approbiert
RE-Y(St)Y-fl-TIMF & RE-Yw(St)Yw-fl-TIM

RE-Y(St)Y-fl-TIMF & RE-Yw(St)Yw-fl-TIM

INSTRUMENTATION CABLES, EN 50288-7MULTİ-TRIPLE, PVC INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHED Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / White / Red; with numbered tape under , separator tape of the pair screen, Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,…, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple TIMF Construction: Polyester tape above the triple, AL-PES tape, over solid tinned copper drain wire, 0,60 mm, Upon request ; Stranded 0,50 mm2 copper drain wire Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 190 pF/m, 0,75 mm2 : max. 190 pF/m, 1,0 mm2 : max. 190 pF/m, 1,3 mm2 : max. 200 pF/m, 1,5 mm2 : max. 200 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2Y(St)Y & RE-2X(St)Y

RE-2Y(St)Y & RE-2X(St)Y

INSTRUMENTATION CONTROL CABLES, EN 50288-7RE-2Y(St)Y,ÇOK DAMARLI, PE YALITIMLI, GENEL EKRANLI, PVC KILIFLIRE-2X(St)Y,ÇOK DAMARLI, XLPE YALITIMLI, GENEL EKRANLI, PVC KILIFLI These cables are used for control purposes (e.g. controlling of pumps, valves or engines) at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. For application of 90oC heat resistant, RE-2X(St)Y cables are suitable. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black cores numbered 1-2-3…, Other core configurations manufactured upon request. Lay-up: Cores laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (2Y): PVC comp., flame retardant; EN 50290-2-22 Outer sheath (2X): PVC compound, 90 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Rated voltage: 500V Standard: TS/DIN EN 50288-7 Conductor resistance: 0,50mm2 : 36,0 Ω/km, 0,75mm2 : 24,5 Ω/km, 1,0mm2 : 18,1 Ω/km, 1,3mm2 : 13,9 Ω/km, 1,5mm2 : 12,1 Ω/km, 2,5mm2 : 7,4 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: max. 120 pF/m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω, 2,5mm2 : 60 µH/Ω Test voltage: Urms core-core : 2000 V, Urms core-screen : 2000 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4
RE-Y(St)YSWAY-fl-MP

RE-Y(St)YSWAY-fl-MP

INSTRUMENTATION CABLES, BS 5308 PART 2 TYPE 1SİNGLE & MULTİ-PAİR, PVC INSULATED, COLLECTİVE SCREENED,ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 0,75 mm2 flexible, or, 1,5 mm2 stranded Insulation: PVC compound, TI1, BS 6746 Core identification: According to BS 5308 Part 2 colour coded, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: PVC compund, TM1, BS 7655, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Standard: BS 5308 Part 2 Type 2 Insulation thickness: 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 25 MΩ.km Mutual Capacitance: max. 250 pF/m Capacitance unbalance: (1 kHz) : max. 450 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
Zipper Ladekabel 2in1

Zipper Ladekabel 2in1

2 in1 Ladekabel USB auf MicroUSB und Lightning im Reißverschluss Design, Aufbewahrung ohne Verknoten, 50cm Artikelnummer: 1035834-0 Gewicht: 20g Maße: 1x50cm Verpackung: Polybeutel Verpackungseinheit: 1
Ladekabel HEJU Rake

Ladekabel HEJU Rake

So macht Laden Laune: Lightning-Kabel mit integriertem Micro- USB-Stecker. Komfortable Kabellänge von einem Meter – da zieht garantiert keiner mehr den Kürzeren. Artikelnummer: 1091026-1 Druckbereich: 10 x 10 mm Gewicht: 20 g Maße: 1000 x 14 x 7 mm Verpackung: Polybeutel
Zipper Ladekabel 2in1

Zipper Ladekabel 2in1

2 in1 Ladekabel USB auf MicroUSB und Lightning im Reißverschluss Design, Aufbewahrung ohne Verknoten, 50cm Artikelnummer: 1035834-7 Gewicht: 20g Maße: 1x50cm Verpackung: Polybeutel Verpackungseinheit: 1
Spiralkabel aus Semoflex® Elektronik geschirmt

Spiralkabel aus Semoflex® Elektronik geschirmt

Dieser Spiralkabel-Typ, wird beispielsweise in der Medizinelektronik, für Maschinensteuerungen und im KFZ-Bereich, für Messgeräte und Positionsschalteranschlüsse eingesetzt. Die Spiralkabel für den Elektronikbereich (z.B. Medizinelektronik, Messgeräte, Positionsschalteranschlüsse, Maschinensteuerung). Durch den PolyurethanAußenmantel und die Semocore Aderisolation erreichen wir jetzt auch für Spiralkabel von 0,14–0,50mm² hohe Rückstellkräfte und eine lange Lebensdauer. Die geschirmten Ausführungen haben durch die Verwendung eines speziellen Kupferschirmes vergleichsweise hervorragende Rückstellkräfte.
BayEnergy® N2XY-O  0,6/1 kV  4-5-adrig

BayEnergy® N2XY-O 0,6/1 kV 4-5-adrig

Starkstromkabel für höhere Leitertemperaturen, insbesondere für Kraftwerke, Industrie- und Schaltanlagen, sowie Ortsnetze, falls kein erhöhter mechanischer Schutz erforderlich ist. Im Innen- und Außenbereich, im Freien, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, falls kein erhöhter mechanischer Schutz erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
3 in 1 Ladekabel in Sonderform

3 in 1 Ladekabel in Sonderform

Handy Ladekabel 3 in 1 Ladekabel in Sonderform. Tolles Technik Gadget Ladekabel ca. 15 cm lang mit iPhone 5/6/7, Type C und Micro USB Anschluss. Kabel weiß, Sonderform 4C im Preis enthalten im PE-Beutel verpackt. 5 Volt, 1 Amp. Artikelnummer: 1336900 Gewicht: 60 g Maße: ca 150 - 180 mm Zolltarifnummer: 85444290
BayEnergy® N2XCWY  0,6/1 kV  3-adrig

BayEnergy® N2XCWY 0,6/1 kV 3-adrig

Starkstromkabel für höhere Leitertemperaturen zur Energieverteilung in Kraftwerken, Industrie- und Schaltanlagen, sowie Ortsnetzen. Im Innen- und Außenbereich, im Erdreich, für Kraftwerke, Industrie- und Schaltanlagen, sowie in Ortsnetzen, wenn ein Schutz gegen Berührungsspannung bei mechanischer Beschädigung erforderlich ist. (Siehe DIN VDE 0298-1). Die Aderisolierung aus VPE erlaubt eine höhere Betriebstemperatur und eine höhere Belastbarkeit im Kurzschlussfall als vergleichbare Kabel mit PVC-Aderisolierung. Die Kabel sind unempfindlich gegen gelegentliche Einwirkungen von Ölen und Kraftstoffen.
SIMH-FR/PF FE 180

SIMH-FR/PF FE 180

HIGH TEMPERATURE, TWISTED PAIR RESISTANT TO FIRE SILICONE CABLES These twisted pairs (pair form) cables fields of use as a control and power supply cable they are fire proof and halogen free cables which, on the basis of a fixed operating mode, can continue with the supply of a power for a period of 180 minutes under the existing fire conditions (at a temperature of 750OC and under the flames ). Also these cables shall satify EN50200 test which is a fire resistant with mechancal shock test (under the conditions at 842oC and mechenical shock) by the classes PH15-PH30-PH60-PH90, if it has requsted, Because of their unique features, they can be used; on the fire alarm systems, lighting systems on the equipment and devices which are connected to the fire alarm devices, in the environments which have no corrosive gases are emitted in the event of fire. These cables are used at metro, schools, airpots, hospitals, etc. Conductor: IEC 60228 Class 5, TS/DIN EN 60228 Class 5, Flexible copper wires, plain; Insulation: Speacial silicone rubber compound Core identification: According to TS HD 308 S2 & VDE 0293-308, Acc. to TS/DIN EN 50334 black cores with, white numerals with green/yellow after 5 cores Lay-up: Cores laid up in layers of optimum pitch Outer sheath: Silicone rubber compound Sheath colour: RAL 2009, Orange Standard: VDE 0250, DIN VDE 0282-15 and, TS HD 22.15 S1, (Designed according to) Insulation resistance: Min. 20 MΩ.km Temp. at conductor: + 180 oC Short circuit tempetarure: +200oC Rated voltage: 300 / 500V Test voltage: 2000 V Temperature range: Fixed: - 60 oC ~ + 180 oC, Mobile: - 25 oC ~ + 180 oC Min. bending radius: Fixed: 4 x D, Mobile: 7,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1, IEC 60332-3 & EN 50266-2-4 Insulation integrity: IEC 60331 , VDE 0472-814 Fire resistant with mechanical shock*Upon request: DIN EN 50200 ; PH 15 (15 minutes), DIN EN 50200 ; PH 30 (30 minutes), DIN EN 50200 ; PH 60 (60 minutes), DIN EN 50200 ; PH 90 (90 minutes)
RE-2Y(St)Y-fl

RE-2Y(St)Y-fl

INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1SİNGLE & MULTİ-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , ,0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type03 Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…) Triple: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
Leiter (bzw. Litze oder Ader)

Leiter (bzw. Litze oder Ader)

Für die Sonderkabelfertigung werden in erster Linie Litzenleiter entweder als Bündellitze oder als konzentrische Litze eingesetzt (z.B. Unilaylitzen, Edelstahllitzen). Der Verwendungszweck eines Kabels hat ganz entscheidenden Einfluss auf die Auswahl des Leiteraufbaus. Man unterscheidet grundsätzlich zwischen Massivleitern, Litzenleitern oder Lahnleitern. Für die Sonderkabelfertigung werden in erster Linie Litzenleiter entweder als Bündellitze oder als konzentrische Litze eingesetzt (z.B. Unilaylitzen, Edelstahllitzen). Bei SENSOCAB reichen die Litzenquerschnitte je nach Aufbau der Leitung - von 0,0019 mm² (AWG 44) bis zu 1,3 mm²(AWG 18). Eine Sonderform ist die Beilauflitze. Die rasche Entwicklung erfordert heute in der Sonderkabelfertigung Leitermaterialien mit großer Leistungsfähigkeit und Zuverlässigkeit. Bei Sensocab werden folgende Litzenmaterialien eingesetzt: • Kupfer - Aufgrund seiner sehr guten elektrischen Leitfähigkeit und seiner hervorragenden Warm- und Kaltverformbarkeit, wird in der Kabeltechnik überwiegend Elektrolytkupfer eingesetzt. Kupfer wird, je nach Verarbeitung und Einsatz, mit unterschiedlichen Oberflächen gefertigt (blank, verzinnt, versilbert). • Alloy - In Anwendungsfällen mit hoher Wechselbiegebeanspruchung und geringen Biegeradien wird häufig die spez. Kupferlegierung “Alloy” eingesetzt. Alloy zeichnet sich durch besonders hohe Zug- und Wechselbiegefestigkeit aus. • StaKu - Staku-Drähte sind Stahlkupferverbunddrähte, bei denen der Stahlkern in einem elektrolytischen Verfahren verkupfert wird, um die Leiter für eine hohe mechanische Beanspruchung zu erhalten. • halbleitende Kunststoffe oder Kohlestofffasern • Lahn - Mit Lahnlitzen werden die besten Ergebnisse bei Wechselbiegebeanspruchung erreicht. Bei den Lahnlitzen wird Textilgarn (Trägerfäden) mit flachgewalzten Drähten (= Laminetten) "umwickelt". Als Trägerfäden werden versch. Materialien z.B. Kevlar, Nylon etc. eingesetzt. Die flachgewalzten Drähte haben eine Dicke von ca. 0,01 - 0,03 mm und eine Breite von ca. 0,20 mm. Als Werkstoffe werden blanke, verzinnte oder versilberte Kupferdrähte eingesetzt.
Ladekabel 3 in 1 Leder Lisa - weiß

Ladekabel 3 in 1 Leder Lisa - weiß

Das elegante Leder Ladekabel Lisa verfügt über der verschiedene Anschlüsse (Lightning, Micro und Typ-C) und kann somit für jedes Mobiltelefon benutzt werden. Das Ladekabel hat eine reine Ladefunktion inkl. Keyring ideal für den Schlüsselanhänger Artikelnummer: 1345433 Breite: 65 Gewicht: 2g Höhe: 10 Kapazität: - Länge: 150 Maße: 65 x 150 x 10 mm
KABELKONFEKTION

KABELKONFEKTION

Wir konfektionieren Kabel passend Ihren Angaben und Vorschriften Individuelle Kabelkonfektion nach Ihren Anforderungen und den gesetzlichen Normen setzten wir in höchster Qualität um. Sie wählen aus mehr als 150 vorrätigen Kabelarten aus, wir verarbeiten diese mit modernsten Werkzeugen und Methoden. Wir bieten folgendes Leistungsspektrum an: - Konfektion von Einzeladern/Litzen, Flach- und Rundkabel, Sonderleitungen, Koaxialkabel, Motorenkabel, Steuer- und Signalleitungen - Konfektion kompletter Draht- und Kabelsätze (Querschnitten bis 120mm², weitere auf Anfrage) - Kundenspezifische Lieferung von Kabel- und Drahtsätze: Gebündelt, beschildert und nach Installationsprozess kommissioniert - Auslegung und Aufbauplanung mit Materialbeschaffung (gesamt oder teilweise) - Keine Lagerkosten durch Just-in-Time-Lieferung - Elektrische Prüfung aller Kabel mittels Testcomputer