Finden Sie schnell testem für Ihr Unternehmen: 716 Ergebnisse

100ADM MK5 Secondary Current Injection Test Set

100ADM MK5 Secondary Current Injection Test Set

0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current limit mode for fine control Automatic mains voltage selection Thermal and over-current protection The 100ADM mk5 Secondary Current Injection Test Set provides commissioning and maintenance engineers with a flexible system for testing protective systems. It has an easy to understand panel layout and a simple user interface. The status of every function can be seen at a glance, and there are no complex menus to navigate. The 100ADM mk5 keeps the familiar user interface of previous models but adds a new metering system that accurately measures the RMS of a single cycle. It also features a new current limit mode to provide very fine control of very low currents, even into low impedance loads. Current limit mode also assists in testing self-powered overcurrent protection as fitted to many 11kV ring main units. The unit has a range of outputs allowing injection of currents as low as a few mA and as high as 100A. Voltages up to 240V are available on the main outputs, allowing high impedance current relays and voltage relays to be tested. Four true RMS metering ranges are provided, allowing the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used on all inputs and outputs for convenience, reliability and safety. The 100ADM Mk5 Secondary Current Injection Test Set is comprehensively protected by overcurrent, duty cycle and thermal trips, and keeps the user fully informed of any trip condition. A stabilised DC supply is provided to power the relay under test, along with an independently switched and isolated 110V AC output. The back-lit display on the 100ADM mk5 is bright and clear with a wide viewing angle. The results of a test can be seen here as they appear on the display A very flexible two channel timing system is provided, allowing trip times, reset times and re-close times to be quickly measured to a high degree of accuracy. The timer auto-ranges to measure from 1ms to 99999.9s. The 100ADM can be used to test many types of single phase secondary protection including: 27/59 Over and under voltage relays 37 Under current 51 IDMT relays 50/76 Instantaneous overcurrent 59G Neutral voltage displacement 79 Auto-reclosers 2 Time delay relays 51G/50G Earth fault relays 67 Directional overcurrent (basic tests) 52 Miniature circuit breakers Tripping relays Thermal relays 90V Voltage regulating relays WEIGHT 23.9 kg DIMENSIONS 560 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Mains lead Output lead set Spare fuses Carry strap OPTIONAL ACCESSORIES 100ADM-F, Part no. 006
Elektronisches Längendehnungsmessgerät

Elektronisches Längendehnungsmessgerät

LD DD1-2 für E-Modulmessungen nach EN 13412 Elektronischer Längendehnungsmesser Typ LD DD1-1 zur Messung der Verformung an zwei Mantellinien. Speziell geeignet für die Bestimmung des Elastizitätsmoduls im Druckversuch an Prismen-Probekörper mit den Abmessungen 40 x 40 x 160 mm
Unser magnetisch angetriebener Hochfrequenzpulsator bis 550 kN für Materialprüfungen

Unser magnetisch angetriebener Hochfrequenzpulsator bis 550 kN für Materialprüfungen

Highlights Hohe Frequenzen Automatische Anrisserkennung Energieeffizient Kurze Prüfzeiten Anwendungen Für Werkstoffuntersuchungen Für Untersuchungen von Bauteilen mit geringem Spiel und Dämpfung Zug-Druck-Schwell-Versuche
Infrarot Thermometer mit Kamera -50°C bis 2200°C: CEM DT-9862S

Infrarot Thermometer mit Kamera -50°C bis 2200°C: CEM DT-9862S

Das Infrarot Thermometer DT-9865 ist ideal für die kontaktlose Messung von Oberflächentemperaturen aus weiter Distanz (75:1 Optik). Es bietet einen großen Messbereich von -50°C bis 2200°C und kann darüber hinaus Lufttemperatur, Feuchtigkeit, Taupunkt- und Feuchttemperatur messen. Mit integrierter digitaler Kamera kann die gemessenen Werten zusammen mit Bilder & Video in hoher Qualität gespeichert werden und durch USB-Kabel auf PC hochgeladen werden. Das Softwarepaket von CEM Instruments bietet Ihnen die Unterstützung für spätere Analyse. Dank des ergonomischen Designs und der umfangreichen Ausstattung ist das Thermometer in unterschiedlichen Gebieten einsetzbar. Die folgenden Informationen helfen Ihnen bei der Auswahl des entsprechenden Produkts für Ihre Aufgabe. Eigenschaften: • 2,2 TFT LCD Farbdisplay • 640 x 480 Pixel (30 Millionen Pixel) Kamera • Fotodatei (JPEG) und Videodatei (AVI) speichern • Max./Min./ DIF/ Durchschnittswerte Rekord • 75:1 Optik • Doppellaser – Messfleckmarkierung • Feuchte und Lufttemperatur • Typ-K Temperatur Messung • Taupunkt- und Feuchtkugeltemperatur • Alarmfunktion • Einstellbare Emission Lieferumfang: • Thermometer DT-9865 • 3,7V Li-Ion-Akku • Type K Temperatur Probe • USB-Kabel • Koffer • Bedienungsanleitung Messbereich: -50 BIS 2200℃ (-58℉ BIS 1832℉) Ansprechzeit: weniger als 150ms Auflösung: 0,1°C(0,1°F) < 1000°C und 1°C(1°F) > 1000°C Grundgenauigkeit (IR): ±1%/±1 °C Optik: 75:1 Emissionsgrad: Einstellbar 0.10~1.0 Typ K Messbereich: -50℃ bis 1370℃ / -58℉ bis 2498℉ Typ K Genauigkeit: ±0.5% Messbereich Taupunkt-/Lufttemperatur: 0 bis 50℃ / 32 bis 122℉ Genauigkeit Taupunkt-/Lufttemperatur: ±0.5℃ / 1℉ Messbereich Luftfeuchtigkeit: 0 bis 100% RH Genauigkeit Luftfeuchtigkeit: ±2.5%RH(20% ~80%RH) Speicher: Max 8GB Micro SD Karte Batterie: ca. 4 Stunden bei Dauereinsatz Abmessungen(H*W*D): 205mm*58mm*125mm Gewicht: 494g
Handhebeladapter PA200

Handhebeladapter PA200

Preisgünstige Prüfvorrichtung speziell für kleine und mittlere Leiterplatten, auch gut als Programmieradapter geeignet. Handhebeladapter PA200
Heizbare Filtergehäuse für Filterkerzen mit "Code 7 Adapter"

Heizbare Filtergehäuse für Filterkerzen mit "Code 7 Adapter"

Die Filtergehäuseteile sind aus Edelstahl 1.4404 (316L) gefertigt, geschliffen und e-poliert (Innen: Ra <0,8; Außen:Ra<1.2). In dem Filterkerzenadapter vom Typ: "Code 7" können Filterkerzen aller namhaften Filterhersteller eingesetzt werden. Die Tankbelüftungsgehäuse sind in L-Ausführung gefertigt, dadurch kann der Tank z.B. zusätzlich Stickstoff-überlagert betrieben werden. Am Einlaßkrümmer befindet sich ein Stäubli-Ventilnippel zur Entlüftung bzw. Entleerung des Kondensats. Über diesen Ventilnippel kann auch das Filtertestgerät "it-01" zur WIT -Prüfung angeschlossen werden. Dokumente, wie Zeichnung, Druckbehälterbescheinigung, ein WAZ 3.1B Materialzertifikat sind im Lieferumfang enthalten. Ist das Filterelement bekannt, so kann auch eine Testparameterliste zur Programmierung des Testgerätes mitgeliefert werden. Durch den Einsatz von selbstregelnden Heizelementen (PTC -Heizern) kann eine aufwendige Temperaturregelung komplett entfallen. Die Heizelemente garantieren, dass die Gehäuse niemals überhitzen und Filter beschädigt werden können Die Heizungen benötigen keine separaten Sicherheits-Thermoschalter zur Not-Abschaltung. Zur Einbindung der Filtergehäuse in bestehende Überwachungsanlagen sind kleine Temperaturanzeigen mit Schaltausgängen oder mit Standard Stromausgängen erhältlich (TCU). Diese Einheiten werden mit TC Klammern oben am Gehäusedom befestigt. Es gibt auch Gehäuseausführungen, die oben am Dom noch einen kleinen TC-25 Anschluß zur Einbringung eines Pt-100 Thermofühlers haben. Heizbare Filtergehäuse für Filterkerzen mit "Code 7 Adapter" 5” Doppelwand-Tankbelüftungs-Filtergehäuse mit PTC-Heizelementen G-002-Hzg-L
Consulting

Consulting

feines Ergebnis. Ein Ergebnis, das Freude bereitet. Allen Beteiligten. Gemeinsam mit unseren Kund:innen streben wir immer ein Ergebnis an, das sich organisch in ein System integriert. Ein Ergebnis, das funktioniert und den öffentlichen Auftrag unterstützt . Ein Ergebnis, das inspiriert und dadurch weitergetragen wird.
Rohrleitungsbau

Rohrleitungsbau

Wir geben unseren Kunden eine umfassende Beratung bezogen auf ihre individuellen Anforderungen. Und bei auftretenden Problemen bieten wir Ihnen schnelle Hilfe rund um die Uhr an. Wir führen Reparaturen sowie andere Arbeiten ordnungsgemäß durch.
Workshop

Workshop

"Mit unseren Workshop- und Trainingsangeboten versetzen Sie Ihre Mitarbeiter in die Lage, mithilfe von additiver Fertigung Kosten- sowie Technikpotentiale zu identifizieren.
Leichte Sprache

Leichte Sprache

Die Implementierung von vereinfachter Sprache auf Ihrer Website kann das Kundenverständnis für Ihre Produkte verbessern und die Verkaufschancen erhöhen. Leichte Sprache ist eine Form von Sprache, die besonders einfach und leicht zu verstehen ist. Sie wird oft verwendet, um Informationen und Texte für Personen zugänglicher zu machen, die Schwierigkeiten beim Lesen oder Verstehen komplexer Texte haben. Leichte Sprache verwendet kurze Sätze, klare Wörter und wenige Fachbegriffe, um sicherzustellen, dass die Informationen leicht verständlich sind.
Montageablauf

Montageablauf

Insgesamt ist die Renovierung von Fenstern eine wichtige Maßnahme, um den Komfort und die Energieeffizienz eines Hauses zu verbessern. Dies erfolgt in nur wenigen Arbeitsschritten: Schritt 1 Zuerst werden die Halter angeschraubt. Schritt 2 Der vorgefertigte Rahmen wird auf die Halter und Flügel geclipst. Schritt 3 Anschließend werden die Fugen zwischen dem Aluminiumrahmen und der Glasscheibe versiegelt.
Turbolader

Turbolader

Das wichtigste oder „beste Stück“ des Turbomotors ist der Turbolader. Statt „bigger is better“ zielt unsere Entwicklung immer darauf ab, ein breites Leistungsband nutzen zu können. Hierzu gehört sowohl hohes Drehmoment schon bei niedrigen Drehzahlen als auch ein schneller Druckaufbau. Das geht mit Spitzen-Wirkungsgraden, breiten Kennfeldern und vor allem einer abgestimmten Zuordnung der einzelnen Turbolader-Komponenten und der Anpassung auf das spezifische Fahrzeug-Umfeld. Hierfür betreiben wir erheblichen Aufwand, u.a. mit einer eigenen aufwändig entwickelten Berechnungs- und Simulations-Software. Damit kann das interne Zusammenwirken von Verdichter und Turbine optimiert werden. Auch werden verschiedene Motor- und Umgebungsbedingungen simuliert. Anschließend werden die Turbolader im praktischen Motorbetrieb gemessen. Beispiel die Werte des ETG-Spezialladers für den 951 auf Basis des „großen“ K26/8, der locker für über 380 PS ausreicht im Vergleich zum „kleinen“ K26/6, der bei 270 PS ausgereizt ist. Beim Beschleunigen aus niedriger Drehzahl im 3. Gang bringt der „große“ ETG-Lader das Drehmoment von 360 Nm genauso früh wie der „kleine“ K26/6 im getunten Motor. Noch früher ist der Kraftaufbau in Verbindung mit der ETG-Downpipe und -Drucksteuerung (In den Diagrammen als ersichtlich). Auch liegt das Drehmoment bei 2.500 oder 3.000 U/min höher. Sämtliche gemessenen Fremdlader namhafter Hersteller liegen weit dahinter. Grafisch wird der bessere Kraftaufbau durch ETG-Lader und –Umfeld gut vergleichbar. Die lästige Trägheit stellt den fühlbaren Gegensatz zum Kraftaufbau bzw. Ansprechen dar. Für den 951 bieten wir eine gestufte Palette von Turboladern. Diese sind auf Basis K26/6 (220 PS-Modell) Überholung 1:1 – Endleistung 260-270 PS je nach Kat / Abgasanlage Upgrade auf Verdichter vom Turbo S – Leistung ca. 285 PS Upgrade auf gefrästen Verdichter neuester Technologie – 290 PS Top-End-Upgrade mit trägheitsreduziertem Turbinenläufer – 300 PS Gegen Aufpreis können auch K26/6-Lader zum großen K26/8-Lader umgebaut werden. K26/8 (250 PS-Modell) Überholung 1:1 – Endleistung mit Serienumfeld rund 300 PS (EG) Upgrade auf ETG-Spezial-Verdichter mit originaler Optik Upgrade mit trägheitsreduziertem Top-End-Turbinenläufer Sonder-Lader für Rennzwecke 3,0-Liter-Motoren bieten wir je nach Einsatz verschiedene Stufen an: Auf Basis K26/8 – Umbau auf speziellen Läufer und K27-Verdichter – Umbau auf 10er-Turbinengehäuse mit K27-Verdichter auf Basis K27.2 – 11er-Turbine mit optimiertem Läufer und K27-Verdichter © 2022 ETG - Eichner Technik GmbH.
Programmierbarer digitaler Controller zur präzisen Steuerung von Tests mit 10ns Schrittweite

Programmierbarer digitaler Controller zur präzisen Steuerung von Tests mit 10ns Schrittweite

In Testlaboren müssen parallel zu Messungen oftmals die Testanlage, das Testobjekt oder beides in einer bestimmten zeitlichen Abfolge angesteuert werden. Diese Aufgabe kann jetzt einfacher und flexibler als bisher mit dem SATURN Sequencer von AMOtronics gelöst werden. Die programmierbare digitale Steuereinheit ermöglicht es, Schalter, Leistungsschütze, Relais, IGBTs, MOSFETs und andere Komponenten hochpräzise und synchron anzusteuern. Der Sequencer bietet wahlweise 16, 32 oder 48 digitale Ein-/Ausgänge , welche in Gruppen zu 8 Anschlüssen wahlweise als BNC- oder Lichtwellenleiteranschlüsse ausgeführt werden können. Letztere bieten eine störungsresistente Isolierung gegen Hochspannung, Starkstrom und elektromagnetische Felder. Somit eignet sich das Gerät optimal als HV-Sequencer für Hochleistungs- und Hochspannungstests. Die optische Signalübertragung via Lichtwellenleiter ermöglicht außerdem auch die Überbrückung größerer Entfernungen zur Testanlage bzw. zum Testobjekt. Somit eignet sich der Sequencer auch für andere sicherheitskritische Anwendungen, wie beispielsweise Explosionsexperimente und Impaktversuche. Das Programm zur Steuerung der Sequencer-Ausgänge wird über eine komfortable grafische Bedienoberfläche in der mitgelieferten Software erstellt. Die Taktung erfolgt wahlweise mit 10ns über den internen hoch-präzisen Taktgeber oder synchron zu einem extern bereitgestellten Signal (z. B. Generatorfrequenzen von 16 2/3Hz, 50/60Hz, 400 Hz ... ). Neben einer rein sequentiellen Abarbeitung der Sequenzen werden auch Schleifen und Fallunterscheidungen (Verzweigungen) unterstützt. Nachdem das erstellte Programm auf den Onboard-FPGA (Field Programmable Gate Array) des Sequencers heruntergeladen wurde, wird es unabhängig vom Betriebssystem in Echtzeit abgearbeitet Der SATURN Sequencer steht wahlweise als eigenständiges Steuergerät oder als Ergänzungsmodul für SATURN Transientenrekorder zur Verfügung. Bei der letztgenannten Kombination können neben digitalen Eingängen auch die vom Transientenrekorder gemessenen analogen Signale überwacht werden. Auf diese Weise kann der Sequencer auf nahezu beliebige externe Ereignisse reagieren. Zusätzlich ermöglicht es diese Einsatzvariante, die ausgegebenen Steuersignale des Sequencers parallel zu den Messsignalen des Transientenrekorders aufzuzeichnen und beide anschließend im Detail zu analysieren und auszuwerten. Weitere Details auf der Produktseite des SATURN Sequencers...
Dienstleistungen

Dienstleistungen

Maswer – Ihr Dienstleistungspartner für Qualitätssicherung, Nacharbeit und operative Unterstützung entlang des gesamten Produktlebenszyklus. Ob Automobilindustrie, Maschinenbau, Elektronik oder andere Branchen – wir bieten maßgeschneiderte Lösungen für individuelle Kundenbedürfnisse, branchenübergreifend und zuverlässig.
PCU1-SP MK2 Primary Current Injection Test Set

PCU1-SP MK2 Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The PCU1-SP mk2 is a medium powered primary current injection set offering output currents up to 5000A (11.5kVA for 40seconds). The system consists of a separate control unit containing all metering and control functions and a loading unit, such as the NLU200, NLU2000 or the NLU5000, that provides the high current output. The PCU1-SP mk2 are ideally suited to primary current injection, stability testing and circuit breaker testing. In addition, the SP version offers direct-reading CT ratio and polarity tests and a 100A secondary injection output. Two loading units are available, delivering a maximum output current of 2000A or 5000A. Each loading unit has three output taps to allow for a wide range of load impedances. For example, the NLU5000 may be configured to either give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V range or 1250A on the 9.2V range. *The above is an image of the PCU1-SP and Loading Unit The control unit is rated at 11.5kVA with a 2 second overload capability of 23kVA using pulse mode. All metering is digital and a memory facility is provided to hold the current reading when the output trips or is switched off. The current is switched by a solid state device and is automatically switched off when the device under test trips. The PCU1-SP systems have a high accuracy timing system, allowing timing tests to be carried out to a resolution of 1ms. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available to test under and over current devices, re-closers, under and over voltage devices, current trips and circuit breakers. A full range of high current output leads are available to complement the system in a range of lengths. WEIGHT 26 kg DIMENSIONS 450 × 275 × 305 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set OPTIONAL ACCESSORIES Trolley mounting system, Part no A204-0005 100ADM-F, Part no. 006 100AL MK2 / MK3 Lead Set, Part no. A199-0003
HV TROLLEY2 High Voltage AC Test System

HV TROLLEY2 High Voltage AC Test System

20kVA output capability 0-3kV to 0-15kV options available Accurate digital metering Key operated supply switch Dual overload protection Variable electronic trip 10-110% of rated output Voltage and current metering Optional 5s – 5min test timer External 24V interlock and zero-volt interlock Emergency stop switch The HV trolley2 series of units are high power AC flash test sets with a 20kVA output capability. Single Trolley Version The maximum output voltage can be customised to be any voltage up to 15kV. The unit is housed in a rugged aluminium enclosure with a cover to protect the control panel. It is mounted on wheels to allow easy movement within a production environment. The HV trolley2 is provided with accurate digital voltage and current metering and a variable electronic trip. An external interlock input is also fitted to the unit. Outputs are provided to drive 24V warning beacons. The HV output is connected to the test object by a high voltage cable 5m long.
T 1000 PLUS Secondary injection relay test set

T 1000 PLUS Secondary injection relay test set

Multi-tasking test set designed for testing relays and transducers Max current output: 250 A Max AC voltage output: 250 V Max DC voltage output: 300 V Frequency generator: 15 ÷ 550 Hz Phase angle shifter Battery simulator 20 ÷ 260 V DC Oscilloscope function for current and voltage USB port – Microprocessor controller Test results and settings saved into local memory TD 1000 Plus model with two current outputs and high power at 15 Hz. T1000 PLUS is a protective relay test set especially designed to give the commissioning engineers a multitasking and highly reliable testing equipment. Tests performed Distribution relays Smart grid relays Single phase relays High burden relays
Stoil Cell For dielectric oil test

Stoil Cell For dielectric oil test

Oil cell for the HV test of dielectric oil The option allows the testing of the insulation characteristics of the oil by checking if there is no contamination. Main features Maximum test voltage: 12 kV Cell volume: about 1l Capacitance of the empty cell: 60 pF. Tests performed Tangent Delta
CU-Ps Primary Current Injection Test Set

CU-Ps Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The CU-Ps primary current injection test set is ideally suited to commissioning and maintenance testing where very high currents are required. The system consists of separate control and loading units for maximum flexibility. The control unit contains all control and metering circuitry, and is linked to the loading unit by control and metering cables. The control unit may be used with one of two loading units providing between 5000A or 6000A for 5 minutes or up to 10 or 12kA for short periods. Each loading unit has two outputs which may be connected in series or parallel for maximum flexibility. For example, the PLU-6k may be configured to either give a maximum current of 3000A at 6.6V or 6000A at 3.3V. The control and loading units are each housed in tough steel cases fitted with castors and protective lifting handles. The loading units have a small plan area to allow them to be positioned as close as possible to the test object, minimising power requirements and maximising the available current. The CU-Ps control unit is shown here with a PLU-6k loading unit. This combination may be used to inject currents of up to 6000A for 5 minutes or 12000A for 1 second. The CU-Ps primary current injection test set is ideally suited to all primary current injection tasks, including testing under and over current relays, circuit breakers and CT ratio testing. The control unit is rated at 20kVA and has digital metering. A memory facility is provided on the metering to hold the current reading when the output trips or is switched off. The current is automatically switched off when the device under test trips. The CU-Ps systems have a high accuracy timing system with 1ms resolution. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available for under and over current devices, reclosers, under and over voltage devices, current trips and circuit breakers. The AC output current is metered by a true RMS memory ammeter (acquisition time 20ms) with a liquid crystal display. The current metering has 3 ranges corresponding to 10%, 50% and 100% of the maximum rating of the loading unit. In addition, a 200% metering range is enabled in pulse mode for the 0.2s, 0.5s and 1s settings only. The CU-Ps systems have a flexible timing system with two contact inputs and 5 operating modes. Each contact circuit automatically selects for N/O or N/C contacts, and the status of each contact input is shown by an LED. The timing channels may also be triggered by a dc voltage between 24 and 240V. *Pulse mode applies current to the load for a maximum of the specified time. If contact set 1 changes state or the current drops below 20% of the metering range during the pulse time, the timer is stopped. The maximum output current is increased in pulse mode. The maximum obtainable current is set by the impedance of the test object and output leads. **Current operated mode is used to time circuit breakers with no auxiliary contacts. The timer is started when the current exceeds 20% of the selected metering range (e.g. 1000A on the PLU-5k 5000A range). The timer stops when the current falls. All test results from the CU-Ps can be stored in a USB memory key. The unit has a real-time clock to time and date-stamp all results. To log the results, first enter a comment for your results using the optional keyboard, and then select AUTO STORE. Whenever the timer stops, the time, current and all other parameters are added to a spreadsheet file on the USB key. You can then view the current set of results on the display or take the USB key out and open the file on your PC. All results are stored in a folder on the USB key named with the test date in a file named with the time. The CU-Ps primary current injection test sets and loading units are CE marked and are designed to meet the requirements of BS EN61010. The system is protected by electronic trips on the outputs, circuit breaker and fuse on the mains input, and a circuit breaker on the control unit output. The unit also has a duty cycle trip on the loading unit output and thermal protection. WEIGHT 115 kg DIMENSIONS 660 × 400 × 740 mm OPTIONAL ACCESSORIES A range of output lead sets are available to complement the CU-Ps system with current ratings between 3000A and 6000A. The leads are double insulated and have good flexibility. SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set
Bump Tester und Gas Kalibrator

Bump Tester und Gas Kalibrator

Gesetzliche Vorschriften und die Notwendigkeit des täglichen Stoßprüfens erzeugen ein starkes Bedürfnis von Gastests. Gasdetektoren spielen eine wichtige Rolle für die Sicherheit von Menschen und Anlagen. Calibration Gas Description Ni-Br regulator Stainless steel regulator Non-reactive gases Suitable Suitable H2S Suitable Suitable SO2 Suitable Suitable NO Not recommended Suitable NO2 Not recommended Suitable Cl2 Not suitable Suitable NH3 Not suitable Suitable HCL Not suitable Suitable PH3 Not suitable Suitable SiH4 Not suitable Suitable HCN Not suitable Suitable
DRTS 6 Automatic relay test set

DRTS 6 Automatic relay test set

Main features Multi-tasking relay test equipment designed for testing protection relays, energy meters, transducers Output: 6×15 A (80 VA); 4×300 V (85 VA); 1×260 V DC High accuracy outputs: 0.1 %; 0.05% (HP) Analog measurement inputs IEC 61850 protocol interface USB and RS232 port Controlled by PC laptop or local control by PDA Tests performed Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 3 PLUS Automatic relay test set

DRTS 3 PLUS Automatic relay test set

DRTS 3 PLUS power system simulator is designed to give the highest accuracy when testing and calibrating protective relays, energy meter, transducer and power quality devices. This diagnostic and calibration equipment is the perfect solution to perform automatic testing on protection devices. Main features Multi-tasking relay test equipment designed for testing protection relays, energy meters, transducers Output: 3×15 A (100 VA); 4×300 V (85 VA); 1×260 V DC High accuracy: better than 0,05% Analog measurement inputs IEC 61850 communication Protocol interface USB and RS232 port Controlled by PC laptop or local control by PDA Lightweight Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 66 – Automatic relay test set

DRTS 66 – Automatic relay test set

DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available. Main features Manual control of the display 6 Current and 6 Voltage generetors plus 1 battery simulator outputs Current outputs : 6 x 32 A, 3 x 64 A, 1 x 128 A Power outputs: 6 x 430 VA, 3 x 860 VA, 1 x 1000 VA Voltage outputs: 6 x 300 V at 100 VA High accuracy outputs: better than 0.05% IEC 61850 protocol interface USB and ethernet interface Advanced testing and data management software TDMS Complete library of relays from the major manufacturers Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays High burden relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 66 – Automatic relay test set

DRTS 66 – Automatic relay test set

DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available. Main features Manual control of the display 6 Current and 6 Voltage generetors plus 1 battery simulator outputs Current outputs : 6 x 32 A, 3 x 64 A, 1 x 128 A Power outputs: 6 x 430 VA, 3 x 860 VA, 1 x 1000 VA Voltage outputs: 6 x 300 V at 100 VA High accuracy outputs: better than 0.05% IEC 61850 protocol interface USB and ethernet interface Advanced testing and data management software TDMS Complete library of relays from the major manufacturers Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays High burden relays Low power relays DC relays Energy meters Transducers Power quality meters
T 3000 Primary current injection test set

T 3000 Primary current injection test set

T 3000 is a primary current injection testing system designed to perform primary tests requested in substations commissioning. It allows to perform different tests and measurements on current transformers, voltage transformers, power transformers, protection relays, energy meters and transducers Main features Multi function primary test system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities 3000 V AC high-pot test Generates up to 800 A (option up to 4000A with high current booster) Microhmmeter function (option): up to 400A DC RS232 interface for pc connection Possibility to store test results in T 3000 local memory (up to 500 results) Compact and lightweight. Tests performed CT ratio CT ratio voltage mode CT polarity CT burden secondary side CT excitation curve CT knee voltage CT winding resistance Burden resistance VT ratio VT polarity VT burden secondary side PT ratio PT winding resistance Distribution relays Smart grid relays Single phase relays High burden relays CB operation time
STS 3000 LIGHT Multifunction substation test set

STS 3000 LIGHT Multifunction substation test set

STS 3000 light is a testing system designed to perform Tan Delta and capacitance measurement on CTs, VTs, Power Transformer and Circuit Breaker Main features Fully automatic Variable output frequency: 15 – 500 Hz Output voltage up to 12 kV Power dissipation factor test with the module TD 5000 ( voltage up to 12 kV) PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Compact and lightweight. Tests performed Tangent Delta Capacitance
STS 3000 LIGHT Multifunction substation test set

STS 3000 LIGHT Multifunction substation test set

STS 3000 light is a testing system designed to perform Tan Delta and capacitance measurement on CTs, VTs, Power Transformer and Circuit Breaker Main features Fully automatic Variable output frequency: 15 – 500 Hz Output voltage up to 12 kV Power dissipation factor test with the module TD 5000 ( voltage up to 12 kV) PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Compact and lightweight. Tests performed Tangent Delta Capacitance
20A DC booster Winding resistance test

20A DC booster Winding resistance test

Maximum output current: 20 A DC Maximum power on output sockets: 400 W Current output switch: controlled by STCS Current output amplitude: controlled by STS 5000 or STS 4000 The 20A DC STCS booster allows to perform resistance tests on a PT with a current up to 20 A DC. The option is used together with STS 5000 and STS 4000 and must be connected to STCS module.
WIKA Typ CPA8001 – Druckcontroller Air Data Test Set

WIKA Typ CPA8001 – Druckcontroller Air Data Test Set

Über die Front austauschbare Referenzsensoren Großer Farb-Touchscreen mit allen notwendigen Informationen Regelstabilität 0,001 % der Spanne Genauigkeit bis 0,009 % IS-50 (IntelliScale) Anwendungen Höhen- und Steigratenkalibrierung Fluggeschwindigkeitskalibrierung Kalibrierung von Luftdatenrechnern Militärisch und zivil genutzte Hubschrauber Forschungs- und Entwicklungslaboratorien Besonderheiten Über die Front austauschbare Referenzsensoren Großer Farb-Touchscreen mit allen notwendigen Informationen Regelstabilität 0,001 % der Spanne Genauigkeit bis 0,009 % IS-50 (IntelliScale) Beschreibung Anwendung Das Air Data Test Set CPA8001 (ADTS) ist ein Druckcontroller, der speziell für die Kalibrierung von Messgeräten der Luft- und Raumfahrttechnik konzipiert ist. Mit dem Controller CPA8001 können Kalibrierungen sowohl von analogen Höhenmessern, Steigratenanzeigen und Fahrtenmessern als auch digitalen Sensoren oder Luftdatenrechnern durchgeführt werden. Aufgrund des modularen Aufbaues bietet das Air Data Test Set Typ CPA8001 ein Maximum an Flexibilität in Sachen Konfektionierung nach Kundenwunsch. Aufbau Das CPA8001 ist wahlweise als Tischgerät oder 19″-Einbausatz erhältlich. Das Gerät verfügt über zwei Regeleinheiten mit dem Referenz-Drucksensor CPR8001. Die Sensoren lassen sich über die Front, ohne Ausbau des kompletten Controllers z. B. aus einer Kalibrieranlage tauschen. Funktionalität Ein großer, hochauflösender Farb-Touchscreen, gepaart mit einer intuitiven und bedienerfreundlichen Menüführung, gewährleistet maximalen Bedienkomfort. Die Menüführung steht in einer Vielzahl von Landessprachen zur Verfügung. Auf dem großen Touchscreen sind alle notwendigen Informationen wie aktuelle Mess- und Sollwerte für Höhe, Steigrate, Geschwindigkeit und Beschleunigung auf einer Oberfläche zu finden. Optional können die gemessenen Werte zusätzlich in Druckeinheiten angezeigt werden. Darüber hinaus ist das Erstellen komplexer Testprogramme einfach via Menü am Gerät umsetzbar. Der Controller kann über die vorhandenen Schnittstellen ferngesteuert werden. Hierzu steht eine Vielzahl an Befehlssatz-Emulationen anderer ADTS-Geräte zur Verfügung. Komplette Prüf- und Kalibriersysteme Bei Bedarf können auch komplette mobile oder stationäre Prüfeinrichtungen konfektioniert werden. Für die Einbindung in bereits bestehende Systeme steht für die Kommunikation mit anderen Geräten eine IEEE-488.2-, RS-232-, USB- und Ethernet-Schnittstelle zur Verfügung.
Ähnliche Suchen