Finden Sie schnell tewst für Ihr Unternehmen: 175 Ergebnisse

TD 5000 Tan delta test set

TD 5000 Tan delta test set

The high-voltage generator TD 5000 is a complementary module of STS serie. TD 5000 designed to perform Tan Delta measurements, dissipation factor and capacitance of transformer and bushing at the frequency of the mains or in a wide frequency range. Main features Optional module for STS 5000 and STS 4000 test set, standard module for STS 3000 light Tan Delta, capacitance, dissipation factor measurements and for exciting current test Output voltage from 12 V up to 12 kV Variable output frequency: 1 – 500 Hz PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report Compact and lightweight Patented technology Tests performed Tangent Delta Capacitance Dissipation factor
I-Test eine vollautomatische Lösung für das Testen und Verifizieren von Gas-Pro und T4

I-Test eine vollautomatische Lösung für das Testen und Verifizieren von Gas-Pro und T4

I-Test ist eine vollautomatische Lösung für das Testen und Verifizieren von Gas-Pro und T4, sodass diese in funktionsfähigem Zustand ihre Arbeit verrichten. Specifications Size 110 x 250 x 320mm (4.3 x 9.8 x 12.6 ins) Weight 2kg (70.5oz) Alarms 9-12V @ 3A I-Test backup battery 200 speedy bump tests with 15 second intervals bewteen tests 5 hours in standby with no bump test Battery life approximately 500 cycles Charge time 7 hours RTC backup battery 3 year life USB interface One standard USB type A socket for USB Flash Memory stick One standard USB type B socket for connections to PC Inlets/Outlets Single gas inlet (requires demand flow regulator) Purge inlet (air) Exhaust Regulators Demand flow regulator required Storage capacity Internal 2GB MicroSD card Temperature specifications Operating temperature: -10°C to +50°C Storage temperature: -25°C to +60°C Charging temperature: 0°C to +40°C Humidity 0% and 95% relative humidity (non-condensing) at +40°C Ingress protection IP20
KV30-40D MK3 Test System

KV30-40D MK3 Test System

The output voltage and current are metered by large, accurate true RMS digital meters 0-30kV output voltage 1.2kVA output capability Key operated supply switch to prevent unauthorised operation Dual overload protection Variable electronic trip – 10-110% of rated output Test timer Voltage and current metering Zero-volt interlock External 24Vdc interlock circuit Visual indication of test piece failure The KV30-40D MK3 Test System is a high voltage general purpose test instrument designed for testing insulation systems and the measurement of breakdown voltage on electrical plant and components. The unit has an output voltage variable from zero to 30kV with accurate metering on both the output voltage and current. A zero-voltage interlock is provided, ensuring that the output may only be energised with the voltage control at zero. The output voltage and current are metered by large, accurate true RMS digital meters. The meters are backlit and have a digit height of 19mm. The test object and output are protected by an adjustable current trip. The trip level may be set to 10-110% of the rated output in 10% steps. Breakdown of the test object is visibly indicated. The unit must be manually reset after a trip condition before testing can be resumed. A pre-selectable test timer is provided for timed tests of 5, 10, 15, 20, 30 seconds, 1, 2, 3 or 5 minutes. An alarm sounds when the test time has ended. The units feature automatic mains voltage selection and an external 24Vdc interlock circuit for connection of emergency off switches and enclosure interlocks. WEIGHT 42 kg DIMENSIONS 300 × 400 × 470 mm SUPPLIED ACCESSORIES ES30 earthing stick Supply lead Spare fuse set Operating manual Earth lead
KV50-20D MK3 Test System

KV50-20D MK3 Test System

0-50kV output voltage 20mA maximum output current Auto-selecting 115/230V supply voltage Key operated supply switch to prevent unauthorised operation Dual overload protection Variable electronic trip Voltage and current metering External interlock circuit Zero-volt interlock Visual indication of test piece failure Cast resin HV transformer The KV50-20D Mk3 Test System is a low power portable high voltage AC test system designed for insulation testing. This system is equally suited to both development and routine testing of electrical insulation systems and plant. The equipment consists of a control unit and a separate resin cast high voltage transformer linked by a 5 metre control cable. The control unit is housed in a rugged aluminium case with a hinged, removable lid for protection. The high voltage transformer is mounted on a base with swivel castors for mobility. The control unit is fitted with a comprehensive range of facilities for control, metering and protection, including an emergency off switch. The output RMS voltage and current are displayed on digital meters. A variable electronic trip is provided, allowing the trip current to be set to 10-110% of rated output. The KV50-20D Mk3 Test System is designed to be operated with the HV transformer inside an interlock test enclosure. A connector is supplied on the control unit to connect interlock switches, extra emergency stop switches and external 24V beacons. WEIGHT 17 kg DIMENSIONS 380 × 314 × 221 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse
KV5-100 MK3 Test System

KV5-100 MK3 Test System

Continuously variable output voltage 0-5kVAC Variable trip circuit 12mA and 20-120mA Output voltage and current metering Visual and audible indication of test piece failure The KV5-100 MK3 Test System is a general purpose, high voltage test instrument designed for testing insulation systems and the measurement of breakdown voltage on electrical plant and components. The unit has an output voltage adjustable from zero to 5kV with accurate metering on both the output voltage and current. A zero-voltage interlock is provided, ensuring that the output may only be energised with the voltage control at zero. The output voltage is metered by a large, linear analogue instrument with a dual-scale marking of 0-3kV and 0-6kV. Load current is metered by a second analogue instrument with 0-10 scale marking. Two current ranges are selectable: 0-10mA and 0-100mA. The test object and output are protected by an adjustable current trip linked to the current metering range. The trip level may be set to 20-120% of the current metering range on 20% steps. Breakdown of the test object is both audibly and visibly indicated. The alarm must be manually reset after a trip condition before testing can be resumed. The KV5-100 MK3 Test System is supplied in a compact and portable case with permanently connected test leads. The test leads are terminated in crocodile clips. The unit is designed to be used in conjunction with an interlocked test enclosure. WEIGHT 16.5 kg DIMENSIONS 364 × 147 × 262 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse
KV30-100 MK3 Test System

KV30-100 MK3 Test System

0-30kV output voltage 3kVA output capability Key operated supply switch to prevent unauthorised operation Dual overload protection Variable electronic trip – 10-110% of rated output Voltage and current metering External interlock circuit Zero-volt interlock Visual indication of test piece failure The KV30-100 MK2 Test System is a high power, high voltage ac test system designed for insulation testing. This system is equally suited to both development and routine testing of electrical insulation systems and plant. The equipment consists of a control unit and a separate oil filled high voltage transformer, linked by 5 metre supply and control cables. The control unit is fitted with a comprehensive range of facilities for control, metering and protection. The output voltage and current are displayed on large, linear analogue instruments, and a variable electronic trip is provided, allowing the trip current to be set to 10-110% of rated output. The high voltage transformer is housed in an oil-filled steel tank fitted with swivel castors for mobility. The unit uses a high voltage bushing for the HV output, and the other end of the HV winding is earthed. The output of the units are protected by variable electronic trips monitoring the output current, and a fixed over-current trip on the primary of the output transformer. The variable trip is adjustable in 10% steps between 10% and 110% of the rated output current. The input and control supplies are protected by fuses. The KV30-100 MK2 Test System is equally suited to testing capacitive, resistive or inductive test objects. If higher voltage or output power is required, please refer to our KV50-200/KV100-100 data sheet, detailing our 10kVA high voltage systems. WEIGHT 25 kg DIMENSIONS 370 × 480 × 290 mm TRANSFORMER WEIGHT 210 kg TRANSFORMER DIMENSIONS 480 x 460 x 570 mm SUPPLIED ACCESSORIES Supply lead Spare fuse set Operating manual Earth lead
KV50-200 MK3 Test System

KV50-200 MK3 Test System

0-50kV output voltage 5kVA output capability Key operated supply switch to prevent unauthorised operation Dual overload protection Variable electronic trip – 10-110% of rated output Voltage and current metering External interlock circuit Zero-volt interlock Visual indication of test piece failure The KV50-200 MK2 Test System is a high power, high voltage ac test set designed for insulation testing. This system is equally suited to both development and routine testing of electrical insulation systems and plant. The equipment consists of a control unit and a separate oil filled high voltage transformer, linked by 5 meter supply and control cables. The control unit is fitted with a comprehensive range of facilities for control, metering and protection. The system includes a secondary tap metering as standard to ensure accurate voltage metering. The output voltage and current are displayed on large, linear analogue instruments, and a variable electronic trip is provided, allowing the trip current to be set to 10-110% of rated output. The high voltage transformer is housed in an oil-filled steel tank fitted with swivel castors for mobility. The units use a low-discharge oil-filled bushing for the HV output. The KV50-200 MK2 Test System is equally suited to testing capacitive, resistive or inductive test objects. The output of the units are protected by variable electronic trips monitoring the output current, and a fixed over-current trip on the primary of the output transformer. The variable trip is adjustable in 10% steps between 10% and 110% of the rated output current. The input and control supplies are protected by fuses. An earth terminal is provided on the transformer which must be connected to a low impedance local earth. WEIGHT 37 kg DIMENSIONS 370 × 480 × 290 mm TRANSFORMER WEIGHT 220 kg TRANSFORMER DIMENSIONS 570 x 500 x 1020 mm SUPPLIED ACCESSORIES Supply lead Spare fuse set Operating manual Earth lead
Gocator 2800 series

Gocator 2800 series

Dualer Triangulations-Linienprofilsensor / Dual Triangulation 3D Laser Line Profile Sensors Zwei Kameras bieten minimierte Okklusion und maximale Scanabdeckung für Anwendungen wie z.B. die Prüfung von Holzscheiten. Megapixel-Imager, 1280 Punkte je Profillinie Messbreite bis zu 1260 mm Messbereich bis zu 800 mm ___________ Two cameras maximize scan coverage and minimize occlusions for applications such as primary log scanning. Megapixel imager. 1280 points per profile resolution Field-of-view up to 1260 mm Measurement range up to 800 mm
Z-OVR Cable Impedance Test System

Z-OVR Cable Impedance Test System

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The Z-OVR Cable Impedance Test Set is a cable impedance test system for the measurement of impedance of overhead lines and underground cables. The system consists of a separate control unit containing all metering and control functions and an output transformer that provides isolation of the output current and feedback voltage. A current is injected into the line under test and the resultant magnitude and phase angle of the voltage across the line is measured. The current, voltage, phase angle and impedance of the line (Z & X) under test are displayed. In addition, the harmonic content of the voltage and current can be displayed. The unit has data logging facilities using a standard USB memory key. Date, time, current, voltage, phase angle, and frequency are stored to a CSV file on the memory key along with a comment entered using the supplied USB keyboard. Pressing the “store” pushbutton causes a new set of values to be written to the CSV file. The output has three taps (75V, 150V & 300V), allowing the measurement of impedance of a wide range of lines and cables. All metering is true rms. Four current ranges (2.000, 10.00, 20.00 and 100.0A) and three voltage ranges (10.00V, 30.00V and 300.0V) are provided. The output transformer unit uses 6mm safety connectors for all outputs and 4mm safety connectors for inputs. A block of connectors is provided adjacent to the output to allow easy parallel connection of cables for parallel measurements on all three phases. The Z-OVR Cable Impedance Test Set is provided with a set of four 10m 12mm2 duplex measurement cables. These provide a 12mm2 conductor for current injection and a 6mm2 conductor for voltage feedback in each cable. WEIGHT 26 kg DIMENSIONS 450 × 275 × 305 mm SUPPLIED ACCESSORIES Earth lead Spare fuse set Operating manual USB keyboard USB memory key Mains lead 5 metre long 1 x 10m Earth Kelvin connection lead 3 x 10m Overhead Kelvin connection leads Link lead to connect parallel connection block Power and metering interconnection leads 5 metre long OPTIONAL ACCESSORIES Trolley mounting system, Part no. A204-0005
ART3V RELAY TEST SYSTEM

ART3V RELAY TEST SYSTEM

3-f Voltage output from 1-f supply 0-450V f-N output voltage 20VA/phase maximum output Variable Frequency 30-999.9Hz Phase shift ±180.0° Multi-function timing system USB keyboard for comment USB data storage. Ideally suited to testing G59 & G99 schemes Step change of phase and df/dt Large 6.5” back-lit colour LCD Automatic mains voltage selection Fully Programmable test procedures Rugged case and weighs under 9kg The new ART3V Relay Test System brings new features to our range of relay test equipment making it far more adaptable. The new output voltages are higher and have a finer level of accuracy and control. The new full colour LCD provides more test detail, making it easy to understand. The ART3V user interface is an improvement of the DVS3 mk2 allowing simple testing of complex voltage and loss of mains protection systems. The ART3V has vastly improved accuracy, stability, and features. Designed to be the trusted and reliable voltage source for relay testing. The ART3V has been designed using the latest digital technology to generate a highly stable and accurate output with very low distortion. Each phase output is individually adjustable for voltage, frequency and phase angle. The unit is controlled by a simple user interface within defined menus. Values may be either typed in at the capacitive keypad or finely varied using a smooth rotary encoder. Bespoke test procedures can be created for step changes of any output variable at set times or with automatic timing of the response of the relay under test. The ART3V has a colour back-lit display to provide an easy to read user interface. Menu options are selected by dedicated buttons on the panel, allowing easy mode change. All information is displayed including contact set status, and a phasor diagram. The ART3V Relay Test System is ideally suited for testing G59/G99 protection, including loss of mains protection. Vector surge and df/dt (ROCOF) relays can be simply tested and timed, as well as other protection requiring one to three voltages, including: Under and over frequency relays Under and over voltage relays Synchronising relays df/dt & ROCOF relays Vector surge relays Transducers In conjunction with the ART3C or a current source (such as the 200ADM-P), the ART3V can be used to test protection circuits, including: Directional relays Distance protection Phase angle relays Power relays Power transducers Output The output of the ART3V has 4mm safety sockets for phases A, B, C and neutral. The neutral connection may be omitted for a delta connection. The neutrals can be linked for a star connection using the provided accessory. Timing System The timing system on the ART3V is flexible and transparent with different modes of operation. USB Data The ART3V can be connected to a USB keyboard for adding comments to tests. Each test is stored to a USB memory key with each comment. The data is stored in a *.CSV format allowing it to be opened in all types of desktop PC spreadsheet software. Modes of Operation Output Adjust This mode allows full control of frequency, voltage and phase. Phase Lock Mode The frequency and phase of the output can be controlled by an external reference in phase lock mode. The reference may be the mains supply to the ART3V, an external voltage, current. This mode allows testing of directional and distance protection in conjunction with an external current source. Fault Config Mode Fault Config mode allows extra flexibility in testing complex timed events or several sets of values that must be applied to a relay in turn. This mode allows three sets of values to be set in advance (pre-fault, fault, and post-fault values). The ART3V may be set to switch from one state to the next on a change of contact or after a specific time. In addition, the timer may be set to start or stop on any one of the state changes or a change of contact state. This mode allows frequency, phase and voltage to be changed simultaneously if required. Test configurations can be save to USB. More complex configurations can be loaded from the USB, such as a complete G59/G99 relay test, such as relay stability tests. df/dt and ROCOF (Rate Of Change Of Frequency) Loss of mains protection often takes the form of a df/dt relay, sensitive to the rate of change of frequency over time. The ART3V is able to generate a swept frequency output with accurate rates of change of frequency between preset frequencies. WEIGHT 8.9 kg DIMENSIONS 419 × 325 × 195 mm SUPPLIED ACCESSORIES Output lead set Lead set case Mains lead Spare fuse set Operating manual
TAU 12

TAU 12

Schienenstromwandler - Wechselstromnetz - Primärschiene 55x225mm - Primärstrom 2500…8000A - Bürde : 40…70VA - Klasse : 0,5 • Schienenstromwandler - Wechselstromnetz • Primärschiene 55x225mm • Primärstrom 2500…8000A • Sekundärstrom 1A - 5A • Bürde : 40…70VA • Klasse : 0,5
TAU 11

TAU 11

Schienenstromwandler - Wechselstromnetz - Primärschiene 120x165mm - Primärstrom 1500…8000A - Bürde : 20…70VA - Klasse : 0,5 • Schienenstromwandler - Wechselstromnetz • Primärschiene 120x165mm • Primärstrom 1500…8000A • Sekundärstrom 1A - 5A • Bürde : 20…70VA • Klasse : 0,5
TA 327

TA 327

Auftsteckstromwandler - Ø 27 mm - Messung - Kl. 0,5 - 1 - 3 • Aufsteckstromwandler - Wechselstromnetz • Rundleiter und Primärschiene Ø 27mm - 32,5x10,5mm • Primärstrom 50...300A • Sekundärstrom 1A - 5A • Bürde : 1,5...10VA • Klasse : 0,5 / 1 / 3
PRÜFBALL SPB ANALOG – Robuster analoger Spannungsprüfer mit Gummigehäuse

PRÜFBALL SPB ANALOG – Robuster analoger Spannungsprüfer mit Gummigehäuse

Sein einzigartiges Gehäuse aus Gummi kapselt das Messwerk ballartig ein und schützt optimal gegen harte Stöße, Wasser, Staub und elektrischen Schlag. Das macht den Spannungsprüfer unverwüstlich, sicher und langlebig. Der Prüfball SPB ist ein gummigekapselter Spannungsprüfer für den sicheren Einsatz in der Energieversorgung – genau, robust und wartungsfrei. Spannungsprüfer: präzise Anzeige der Spannung 20 – 500 V AC/DC / 50 V – 1000 V AC/DC extrem Spannungsfest – CAT IV 1000 V – VDE zertifiziert eindeutige LED-Anzeige für gefährliche Spannung Lastzuschaltung für Störspannungen und RCD-Auslösung vollständige Spannungsanzeige ohne Batterie – wartungsfrei präzises, störsicheres Drehspul-Messwerk mit direkter Anzeige Durchgangsprüfer: schneller Durchgangstest Phasen- und Drehfeldrichtungsprüfer: Phasenprüfer mit roter LED Anzeige Drehfeldprüfer mit LED Anzeige rechts / links Controller-überwachte Prüfung mit Fehlererkennung zur Vermeidung von Falschaussagen Phasen- und Drehfeldrichtungsprüfer können mit Handschuhen genutzt werden weitere Funktionen: Sicherheitsgehäuse aus Vollgummi extrem stoßfest Prüfelektroden mit Gewinde zum Aufschrauben von Zubehör leichte Bedienung Isolierungsfehler Erkennung durch zweifarbige Leitungsisolierung extrem stabiles Gehäuse, auch bei Kälte IP 65 – wasserdicht
TAU 13

TAU 13

Schienenstromwandler - Wechselstromnetz - Primärschiene 120x225mm - Bürde : 40…70VA - Klasse : 0,5 • Schienenstromwandler - Wechselstromnetz • Primärschiene 120x225mm • Primärstrom 2500…8000A • Sekundärstrom 1A - 5A • Bürde : 40…70VA • Klasse : 0,5
TAU 9

TAU 9

Schienenstromwandler - Wechselstromnetz - Primärschiene 55x165mm - Primärstrom 1500…5000A - Bürde : 20…60VA - Klasse : 0,5 • Schienenstromwandler - Wechselstromnetz • Primärschiene 55x165mm • Primärstrom 1500…5000A • Sekundärstrom 1A - 5A • Bürde : 20…60VA • Klasse : 0,5
TAU 10

TAU 10

Schienenstromwandler - Wechselstromnetz - Primärschiene 120x125mm - Primärstrom 1500…6000A - Bürde : 20…70VA - Klasse : 0,5 • Schienenstromwandler - Wechselstromnetz • Primärschiene 120x125mm • Primärstrom 1500…6000A • Sekundärstrom 1A - 5A • Bürde : 20…70VA • Klasse : 0,5
TAQ 6

TAQ 6

Wickelstromwandler - Wechselstromnetz - Primärstrom 5…100A - Bürde : 6VA (Kl.0,5) - 10VA (Kl.1) • Wickelstromwandler - Wechselstromnetz • Primärstrom 5…100A • Sekundärstrom 1A - 5A • Bürde : 6VA (Kl.0,5) - 10VA (Kl.1) • Klasse : 0,5 / 1
TAIBB

TAIBB

Aufsteckstromwandler - Ø 21 mm - Messung - Kl. 0,5 - 1 - 3 • Aufsteckstromwandler - Wechselstromnetz • Rundleiter und Primärschiene Ø 21mm - 16x12,5mm • Primärstrom 40...300A • Sekundärstrom 1A - 5A • Bürde : 1...7,5VA • Klasse : 0,5 / 1 / 3
HTM - Hydrantentester

HTM - Hydrantentester

inkl. Standfüße, Batterie, Handbuch, Kalibrierzertifikat Nennweiten DN80 und DN100 • Durchflussmessbereich: 100-1500 l/min. bzw. 200 – 2500 l/min • Druck-Messbereich: 0-16 bar (0-10 bar; 0-6 bar) Anzeige am Manometer oder Datenlogger • Alu-Tragegriffe und Standfüsse mit Gummipuffer • Einlauf / Auslauf Beruhigungsstrecken 500 mm lang inkl. Standfüsse für einfachen Auf-/Abbau des Hydrantentesters • Digitalanzeige vor Ort für Durchfluss in l/min; bar; m³/h; m³ • Batteriebetrieb • Integrierter Datenlogger mit Impulsausgang bzw. 4-20 mA Ausgang für ext. Aufzeichnungsgerät / Datenlogger • Manometer; Digitalmanometer oder Drucksensoren mit 4-20 mA für ext. Aufzeichnungsgerät / Datenlogger
TRA 230

TRA 230

Teilbarer Stromwandler - Wechselstromnetz - Bis 400A - Primärschiene 20,5x30,5mm • Teilbarer Stromwandler - Wechselstromnetz • Primärschiene 20,5x30,5mm • Primärstrom : 60…400A • Sekundärstrom : 1-5A • Bürde : : 1…6VA • Klasse : 0,5 / 1 / 3
Original MINIMESS® Speicherfüll- und Prüfvorrichtung

Original MINIMESS® Speicherfüll- und Prüfvorrichtung

Clever, spart Zeit und Kosten: Unsere MINIMESS® Speicherfüll- und Prüfvorrichtung ermöglicht die Befüllung bzw. Überprüfung mehrerer Speicher, ohne dass ein Schließen der Druckquelle, etwa der Stickstoffflasche, notwendig ist. Durch Öffnen des Entlastungsventils nach dem Schließen der Stickstoffflasche erfolgt die Entlastung der Füll- und Prüfvorrichtung.
TAQ 10

TAQ 10

Wickelstromwandler - Wechselstromnetz - Primärstrom 5…300A - Bürde : 10VA (Kl.0,5) - 15VA (Kl.1) • Wickelstromwandler - Wechselstromnetz • Primärstrom 5…300A • Sekundärstrom 1A - 5A • Bürde : 10VA (Kl.0,5) - 15VA (Kl.1) • Klasse : 0,5 / 1
TAQ 20

TAQ 20

Wickelstromwandler - Wechselstromnetz - Primärstrom 5…600A - Bürde : 20VA (Kl.0,5) - 40VA (Kl.1) • Wickelstromwandler - Wechselstromnetz • Primärstrom 5…600A • Sekundärstrom 1A - 5A • Bürde : 20VA (Kl.0,5) - 40VA (Kl.1) • Klasse : 0,5 / 1
TA 540

TA 540

Aufsteckstromwandler - Ø 40 mm - Messung - Kl. 0,5 - 1 - 3 • Aufsteckstromwandler - Wechselstromnetz • Rundleiter und Primärschiene Ø 40mm - 50,5x12,5mm • Primärstrom 300…1200A • Sekundärstrom 1A - 5A • Bürde : 2…15VA • Klasse : 0,5 / 1
TAS 125

TAS 125

Schienenstromwandler - Wechselstromnetz - Primärschiene 127x54mm - Primärstrom 400…4000A - Bürde : 3…200VA (MESSUNG) - 3…50VA (SCHUTZ) - Klasse : 0,5 / 1 (MESSUNG) - 5P5 • Schienenstromwandler - Wechselstromnetz • Primärschiene 127x54mm • Primärstrom 400…4000A • Sekundärstrom 1A - 5A • Bürde : 3…200VA (MESSUNG) - 3…50VA (SCHUTZ) • Klasse : 0,5 / 1 (MESSUNG) - 5P5 / 5P10 (SCHUTZ)
TRA580

TRA580

Teilbarer Stromwandler - Wechselstromnetz - Bis 1000A - Primärschiene 50,5x80,5mm • Teilbarer Stromwandler - Wechselstromnetz • Primärschiene 50,5x80,5mm • Primärstrom : 250…1000A • Sekundärstrom : 1-5A • Bürde : : 1…10VA • Klasse : 0,5 / 1
TA 426

TA 426

Aufsteckstromwandler - Ø 26 mm - Messung - Kl. 0,5 - 1 - 3 • Aufsteckstromwandler - Wechselstromnetz • Rundleiter und Primärschiene Ø 26mm - 40,5x12,5mm • Primärstrom 150...800A • Sekundärstrom 1A - 5A • Bürde : 1,5...12VA • Klasse : 0,5 / 1 / 3
TAQ 1

TAQ 1

Wickelstromwandler - Wechselstromnetz - Primärstrom 5…60A - Bürde : 3VA - Klasse : 1 • Wickelstromwandler - Wechselstromnetz • Primärstrom 5…60A • Sekundärstrom 1A - 5A • Bürde : 3VA • Klasse : 1
TAQ 2

TAQ 2

Wickelstromwandler - Wechselstromnetz - Primärstrom 5…80A - Bürde : 2…6VA - Klasse : 0,5 / 1 / 3 • Wickelstromwandler - Wechselstromnetz • Primärstrom 5…80A • Sekundärstrom 1A - 5A • Bürde : 2…6VA • Klasse : 0,5 / 1 / 3