Finden Sie schnell kabels für Ihr Unternehmen: 470 Ergebnisse

RE-2Y(St)Y-fl-TIMF

RE-2Y(St)Y-fl-TIMF

INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 1MULTİ-TRIPLE, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are tor indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , ,0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type03 Core identification: Black / White / Red; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White / Red cores numbered 1-1-1, 2-2-2,… Triple: Two conductors twisted to a pair TIMF Construction: Polyester tape above the triple, AL-PES tape, over tinned copper drain wire, 0,50 mm2 Lay-up: TIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 0,75 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1
Anschlusskabel | Netzanschlussleitungen

Anschlusskabel | Netzanschlussleitungen

Als Zulieferer der Industrie und des Handels sind wir ein innovativer und absolut zuverlässiger Hersteller von Netzanschlussleitungen, welche wir auf Kundenwunsch konfektionieren. Die harmonisierten PVC-Leitungen sowie alle weiteren Kabel werden am Firmenstandort in Trochtelfingen produziert. Unsere Herstellung von Netzanschlussleitungen ist bis ins Kleinste und darüber hinaus auch länderspezifisch diversifiziert. Standardzuleitungen werden generell in den gängigen RAL-Farben hergestellt. Bei der Herstellung von Netzanschlussleitungen unterscheiden wir beispielsweise in Netzstecker für die Schweiz und England. Und darüber hinaus bieten wir auch für USA, Australien, Italien, Argentinien sowie andere Länder an. Bei den europäischen Leitungen unterscheiden wir im 2-poligen Bereich in Euro-, Kleingeräte- und Konturenleitung, im 3-poligen Bereich in Kaltgeräte-, Warmgeräte- sowie Heißgeräteleitungen, wobei Warmgeräte mit Gummileitungen konfektioniert werden. Außerdem bieten wir verschiedene Verlängerungskabel, z.B. Kaltgeräteverlängerungen oder ein Schuko-Verlängerungskabel. Die Netzanschlussleitung verbindet das Endgerät mit der Steckdose. Zu unserem Portfolio als Hersteller von Netzanschlussleitungen gehören unterschiedliche Steckertypen, Gerätestecker und Gerätedosen, Sonderteile und Adapter oder auch Schutzkontakt-Steckdosen. Hinzu kommen noch vielfältige Kabeltüllen zur Durchführung der Zuleitung mit und ohne Knickschutz. Bei der Herstellung der Meterware werden die verdrillten Kupferlitzen durch Weich PVC isoliert. Eurostecker der Schutzklasse 2 haben eine PVC-Ummantelung und sind bis zu einer Belastung von 2,5 Ampere bei einer Spannung von 250 Volt verwendbar. Der internationale Standard für Stecker und Steckdosen IEC entspricht der deutschen DIN EN 60309. Sind Sie auf der Suche nach einem kompetenten Anbieter von Netzanschlussleitungen? Entscheiden Sie sich für die Produktvielfalt der Plastro Mayer GmbH und lassen sich jetzt direkt vom Kundenservice persönlich beraten.
Koaxialkabel

Koaxialkabel

Koaxialkabel sind die wahrscheinlich verbreitetsten grundlegendsten und am einfachsten zu verstehenden Kabel.
Industry Patchkabel RJ45 Cat.6A PUR

Industry Patchkabel RJ45 Cat.6A PUR

Geschirmte PUR-Leitung zur sicheren und industrietauglichen Datenübertragung in der Automatisierungs- und Feldbustechnik. Die Leitung erfüllt die Forderungen nach ULStyle 20963 und erfüllt die Vorgaben nach Cat7 (elektr. Eigenschaften in Anlehnung an EN50288-4-2). Die Materialien und der konstruktiver Aufbau ermöglichen erhöhte mechanische Beanspruchung (Abrieb, Biegung, Erschütterung etc.) der Leitung. Besondere Eigenschaften: UL-Style 20963, seewasserbeständig, recyclefähig, LABS-frei, RoHs-konform, säure- und laugenbeständig, UV-beständig, hydrolysefest, halogenfrei, ölbeständig, hohe Flexibilität, keine korrosiven Gase, mikrobenfest, keine Brandfortleitung. ‧ vollgeschirmtes RJ45 Patchkabel Cat.6A AWG 26/7 ‧ geeignet für 10 GBit Ethernet (IEEE 802.3an) ‧ Knickschutztülle gespritzt mit integriertem Rasthebelschutz ‧ Kabelmantel PUR ‧ Standardvarianten: 0,3 m, 1,0 m, 2,0 m, 5,0 m, 10,0 m. ‧ Andere Längen auf Anfrage
HF-Kabel Monopolar (4mm Federkorb-buchsen-Stecker mit Schiebehülse / Erbe-ACC/ICC-VIO-Stecker)

HF-Kabel Monopolar (4mm Federkorb-buchsen-Stecker mit Schiebehülse / Erbe-ACC/ICC-VIO-Stecker)

Unsere HF-Kabel stellen eine zuverlässige und sichere Verbindung, zu allen gängigen Generatoren her. Das umfangreiche Sortiment umfasst, sowohl Standardanschlüsse als auch zahlreiche Stecker- Varianten für Sonderinstrumente. • Flexibel und ohne Memory Effekt durch feine verseilte Einzellitzen • Lange Lebensdauer und hohe Korrosionsbeständigkeit durch einzeln versilberte Litzen • Maximale elektrische Sicherheit durch hochwertige Isolationswerkstoffe • Hypoallergen durch hochwertigen Silikonmantel • Standardlänge 3 und 5m (Sonderlängen auf Wunsch) • Sterilisierbar im Autoklav-Verfahren • Getestet nach den einschlägigen Normen 3 Meter:: MC92142
FLRY 25,00mm² blau RoHS konform

FLRY 25,00mm² blau RoHS konform

Litze mit Leiteraufbau Typ B. Asymmetrisch aufgebaute Litzen aus Kupfer. Diese besitzen eine höhere Flexibilität auf Grund der größeren Anzahl von Einzeldrähten Temperaturbereich (3.000h): -40° C bis / to + 105° C Aufbau / Werkstoffe Leiter: weichgeglühtes Elektrolytkupfer CU-ETP1 nach DIN EN 13602 Blank Leiteraufbau gemäß ISO 6722-1 Isolierung: Weich-PVC mit Eigenschaften gemäß ISO 6722-1, Klasse B Shorehärte A: 97 ± 3 Anforderungen: nach ISO 6722, in Anlehnung an LV 112
BKDATA Ethernet Cat. 6 4x2x26/19 AWG

BKDATA Ethernet Cat. 6 4x2x26/19 AWG

Industrial Ethernet Cat. 6 direkt vom Hersteller. Schleppkettentauglich, flammwidirg und UL-approbiert Verkabelung nach EN 50173 Industrial Ethernet Kategorie 6 mit einer Übertragungsrate bis 1.000 MBit/s Erfüllt Echtzeitanforderungen für Industrie 4.0 Für flexible und hochflexible Anwendungen geeignet Schleppkettentauglich, flammwidrig und halogenfrei Ermöglicht Patchkabel-Anwendungen bis max. 60 Meter
Kastenklemme

Kastenklemme

Kastenklemmen, die ihren Einsatz als Leiteranschlussklemmen in Automatengehäusen finden.
Aswich Hot Sell Photovoltaic Firefighter Safety Switch Automatically Rapid Shutdown PV switch

Aswich Hot Sell Photovoltaic Firefighter Safety Switch Automatically Rapid Shutdown PV switch

Aswich developed and launched the ERS series rapid shut down switch(RS switch). After installing the Aswich RS switch, firefighters can remotely turn off the AC power before extinguishing the fire. The quick-shutoff switch will automatically disconnect the internal DC isolation switch after collecting the signal from the power grid. 2P-2P (1string-10string) optional Maximum circuit current 55A Sheet metal material, IP66 protection grade DC Switch disconnect according to EN 60947-1&3 Storage temperature range:-40°C - +85°C Start up (loading) current: average 100mA CE certificated Waterproof Vent valve to avoid condensation inside the shell Multi clock interface type optional (knockout hole / gland / MC4 terminal) Advanced temperature sensor is used to detect the highest temperature in the shell in real time temperature, when the internal temperature exceeds 70 degrees, automatic cut-off switch It is suitable for residential, industrial and commercial photovoltaic systems Warranty: 5years origin: China Warranty:: 5years Protection level: IP66 Current: 40A Pole: 2P-20P
BÜGELGRIFF M.ELEKTR. SCHALTFUNKTION, FORM:B MIT KABEL L=182, A=160, D=M06, PO...

BÜGELGRIFF M.ELEKTR. SCHALTFUNKTION, FORM:B MIT KABEL L=182, A=160, D=M06, PO...

Werkstoff: Kunststoff PA6. Ausführung: mit Feinstruktur, schwarz. Hinweis: Drucktaster mit roter oder grüner LED. Anschlussleitung mit 5 m Länge, die aus der Anschraubfläche des Griffschenkels herausführt. Schutzart: IP65. Montage: Von der Rückseite.
Elektronik für Landmaschinen

Elektronik für Landmaschinen

Elektronik für Landmaschinen, 0,3mm Pich, Traceability, AOI, X-Ray, Boundary-Scan, Flying-Probe-ICT, Muster sowie Serienproduktionen, Schnell und zuverlässig, IPC-A-610 Kl. 2, IPC-A-610 Kl.3
Abrollvorrichtungen

Abrollvorrichtungen

Abrollvorrichtungen sind essenziell für die Steigerung der Effektivität im Materialtransport während des Kabelkonfektionierungsprozesses. Diese speziell entworfenen Systeme ermöglichen ein effizientes Abwickeln von Kabelrollen und tragen somit maßgeblich zur Steigerung von Präzision und Produktivität bei. Ihre primäre Funktion ist es, für ein reibungsloses und kontinuierliches Abrollen der Kabel von den Spulen zu sorgen. Dies gewährleistet eine stetige und kontrollierte Materialzufuhr für die nachfolgenden Produktionsschritte. Die Flexibilität dieser Vorrichtungen, unterschiedliche Kabelarten und -dimensionen aufzunehmen, bietet eine breite Einsatzmöglichkeit in der Kabelkonfektion. Durch die Reduzierung von Stillstandszeiten und Unterbrechungen im Zuführungsprozess tragen die Abrollvorrichtungen effektiv zur Optimierung der Fertigungsabläufe bei. Die Möglichkeit, Spannung und Geschwindigkeit individuell anzupassen, erlaubt eine anpassungsfähige und flexible Handhabung im Produktionsprozess, was die Effizienz weiter steigert.
Wellfedern

Wellfedern

Anwendungsbeispiel: Automatikgetriebe Typ: mehrlagig
Moderne Over-Ear-Kopfhörer, gepolstert ca. 1,5m langes Kabel, weiß

Moderne Over-Ear-Kopfhörer, gepolstert ca. 1,5m langes Kabel, weiß

Diese stylischen Over-Ear-Kopfhörer sind in einem schlichten, komplett weißen Design gehalten und wirken dadurch besonders edel. Die Ohrteile sind mit einem weichen Leder ausgepolstert und sorgen für optimalen Tragekomfort auch bei langer Nutzung. UVP: 19,99 EUR Features: Typ: Over-Ear Kopfhörer Angenehm zu tragen dank gepolsterten Ohrteilen Klarer Sound und tiefe Bässe Trendiges, edles Design 1,50 m langes Kabel Für MP3-Player, Tablet, Smartphone, PC, usw... Ohrteile um 90° drehbar, verstellbarer Bügel Artikel-Nummer 70750: Farbe: Weiß
Belastungswiderstand 25 kW 400V

Belastungswiderstand 25 kW 400V

Der Belastungswiderstand 25 kW 400V ist ein hochwertiges drahtgewickeltes Belastungswiderstandsgerät, das für verschiedene Anwendungen in der Elektrotechnik konzipiert wurde. Mit einer Fertigungstoleranz von +/- 10% und einem robusten Gehäuse mit aluminiumfarbener Hammerschlaglackierung, bietet dieses Gerät eine zuverlässige Leistung. Es ist mit einem eingebauten Nockenschalter ausgestattet, der eine präzise Einstellung des Stroms ermöglicht, und ist in einer fahrbaren Ausführung mit 4 Lenkrollen erhältlich, was die Mobilität und Flexibilität erhöht. Die technischen Daten umfassen eine Nennspannung von 400 VAC, 50 Hz und einen Nennstrom von 36 A, was es zu einer idealen Wahl für professionelle Anwendungen macht. Die Benutzerfreundlichkeit des Belastungswiderstands 25 kW 400V wird durch die Möglichkeit, den Strom lückenlos einzustellen, weiter verbessert. Mit einer Stufenzahl des Grobstellers von 10 und einer Einstellbarkeit von 0,7-36 A, können Anwender die Leistung genau an ihre Bedürfnisse anpassen. Das Gerät ist nicht nur leistungsstark, sondern auch sicher, mit einer Schutzart von IP 20. Mit einem Gewicht von 130 kg und kompakten Abmessungen von 85 x 70 x 120 cm, ist es sowohl robust als auch handlich. Dieses Produkt ist die perfekte Lösung für alle, die eine zuverlässige und flexible Stromlast benötigen.
RE-Y(St)Y-fl & RE-Yw(St)Yw-fl

RE-Y(St)Y-fl & RE-Yw(St)Yw-fl

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-TRIPLE, PVC INSULATED, COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. For application of 105oC heat resistant, RE-Yw(St)Yw cables are suitable. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (Y): PVC compound, 70 oC grade; EN 50290-2-21 Insulation (Yw): PVC compound, 105 oC grade; EN 50290-2-21 Core identification: Black / Blue / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Triple: Three conductors twisted to a triple Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Outer sheath (Y): PVC compound, 70 oC grade; EN 50290-2-22 Outer sheath (Yw): PVC compound, 105 oC grade; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1 Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 100 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 105 oC, ınstallation : - 5 oC ~ + 50 oC
RE-2Y(St)Y-fl-PIMF

RE-2Y(St)Y-fl-PIMF

INSTRUMENTATION CABLES, BS 5308 PART 1 TYPE 1MULTİ-PAİR, PE INSULATED, INDIVIDUAL & COLLECTİVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. These cables are not recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360 , 0,50 mm2 and 1,0 mm2 solid,, 0,50 mm2 flexible or 1,5 mm2 stranded Insulation: PE compound, BS 6234 Type03 Core identification: Black / blue ; with numbered tape under, separator tape of the pair screen, *Upon request ; Black / White cores numbered 1-1, 2-2,… Pair: Two conductors twisted to a pair PIMF Construction: Polyester tape above the pair, AL-PES tape over tinned copper drain wire, 0,50 mm2 Lay-up: PIMF laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Outer sheath: PVC comp., flame retardant; TM1, BS 7655 Sheath colour: RAL 9005, Black Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Mutual Capacitance: 0,50 mm2 : max. 115 pF/m, 1,0 mm2 : max. 115 pF/m, 1,5 mm2 : max. 120 pF/m Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range: operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 6 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1 Standard: BS 5308 Part 1 Type 1 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 1,5mm2 : Class 2
RE-2YCYSWAY-fl

RE-2YCYSWAY-fl

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: Braid of tinned Cu wires, 85% coverage Inner sheath: PVC compound, EN 50290-2-22 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 60332-1
RE-2YCY-fl

RE-2YCY-fl

INSTRUMENTATION CABLES, EN 50288-7SINGLE & MULTI-PAIR, PE INSULATED, COLLECTIVE SCREENED, PVC SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation: PE compound, EN 50290-2-23 Core identification: Black / White cores numbered 1-1, 2-2,…, Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Pairs laid up in layers of optimum pitch Separator: Polyester tape Screen: Braid of tinned Cu wires, 85% coverage Outer sheath: PVC comp., flame retardant; EN 50290-2-22 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range: operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 7,5 x D Flame retardance test: IEC 60332-1 & EN 60332-1
SIMH-SPEC

SIMH-SPEC

HIGH TEMPERATURE (300oC) RESISTANT SILICONE CABLES These silicone insulated cables are used as mobile connecting cables for equipment where high temperatures can arise as well as for ambient air temperature between –60oC and +300 oC. These cables have more resistance against tearing and tensile strength with its speacial formulated silicone compound. These cables are used in all areas of low mechanical load e.g in ship building, power plants, cooking plants, glass and ceramic works,foundaries ,cookies plants, solarium and sauna installations for high power lighting fixtures etc. Conductor: IEC 60228 Class 5, TS/DIN EN 60228 Class 5, Flexible copper wires, plain; Insulation: Speacial silicone rubber compound,300 oC grade Core identification: According to TS HD 308 S2 & VDE 0293-308, Acc. to TS/DIN EN 50334 black cores with, white numerals with green/yellow after 5 cores Lay-up: Cores laid up in layers of optimum pitch Outer sheath: Spea. silicone rubber compound,300 oC grade Sheath colour: RAL 3000, Red Standard: VDE 0250, DIN VDE 0282-15 and, TS HD 22.15 S1, (Designed according to) Insulation resistance: Min. 100 MΩ.km Temp. at conductor: + 300 oC Short circuit tempetarure: +360oC Rated voltage: 300 / 500V ; 450/750 V ≥4,0 mm2 Test voltage: 2000 V ; 2500 V ≥4,0 mm2 Temperature range: Fixed: - 60 oC ~ + 300 oC, Mobile: - 25 oC ~ + 250 oC Min. bending radius: Fixed: 4 x D, Mobile: 7,5 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1, IEC 60332-3 & EN 50266-2-4 Insulation integrity: IEC 60331 , VDE 0472-814 a
LIHH

LIHH

HALOGEN-FREE DATA CABLES These halogen-free unscreened flexible control and interconnecting cables are used in instrumentation and control engineering where low current consumptions are required, e.g. in industrial electronics, computers, information and transmission systems, office machines and precision machines. These cables are used at schools, airpots, hospitals, etc. and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. These cables are not intended for outdoor or underground installation. Conductor: Flexible copper wires, plain;, IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: HFFR compound, HI2 , VDE 0207-23 Core identification: According to DIN 47100 or TS/DIN EN 50334, black cores with white numerals Lay-up: Cores laid up in layers of optimum pitch Separator: Polyester tape Outer sheath: HFFR compound, HM2, VDE 0207-24, HFFR: Halogen-free flame retardant Sheath colour: RAL 7001,Grey Min. bending radius: Fixed: 6 x D, Mobile: 12 x D Standard: VDE 0812 & VDE 0814 & VDE 0245 Insulation resistance: Min. 200 MΩ.km Mutual Capacitance: Max. 120 nF/km Inductance: ~ 0,70 Mh/km Impedance: ~ 80 MΩ Rated voltage: 0,14 mm2 : 350 V, ≥0,25 mm2 : 500V Test voltage: 0,14 mm2 : 1200 V, ≥0,25 mm2 : 1500V Temperature range: Fixed: - 30 oC ~ + 70 oC, Mobile: - 5 oC ~ + 50 oC Flame test: IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
RE-2Y(St)HSWAH & RE-2X(St)HSWAH

RE-2Y(St)HSWAH & RE-2X(St)HSWAH

HALOGEN-FREE INSTRUMENTATION CABLES, EN 50288-7RE-2Y(St)HSWAH,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-TRIPLE, XLPE INSULATED, COLLECTIVE SCREENED, ARMOURED, HFFR SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and outdoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain copper wire, stranded, IEC 60228 Sınıf 2, TS/DIN EN 60228 Sınıf 2 Insulation (2Y): PE compound, EN 50290-2-23; (RE-2Y….) Insulation (2X): XLPE compound, EN 50290-2-29; (RE-2X….) Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Upon request ; Colour coded according to IEC 60189-2, Other core configurations manufactured upon request. Pair: Two conductors twisted to a pair Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over stranded tinned copper drain, wire 0,50 mm2 Inner sheath: HFFR compound, EN 50290-2-27 Armour: Galvenized round steel wire, EN 10257-1 Outer sheath: HFFR compound, EN 50290-2-27 Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: TS/DIN EN 50288-7 Insulation thickness: 0,50mm2 : 0,40 mm, 0,75mm2 : 0,40 mm, 1,0mm2 : 0,40 mm, 1,3mm2 : 0,45 mm, 1,5mm2 : 0,45 mm Conductor resistance: 0,50mm2 : 36,7 Ω/km, 0,75mm2 : 25,0 Ω/km, 1,0mm2 : 18,5 Ω/km, 1,3mm2 : 14,2 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 500 pF/500 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,30mm2 : 40 µH/Ω, 1,5mm2 : 40 µH/Ω Rated voltage: 300V Test voltage: Urms core-core : 1500 V, Urms core-screen : 1500 V Temperature range (2Y): operation : - 30 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 30 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame test: IEC 60332-1 & TS/DIN EN 60332-1, IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
RE-2Y(St)HSWAH&RE-2X(St)HSWAH

RE-2Y(St)HSWAH&RE-2X(St)HSWAH

HALOGEN-FREE INSTRUMENTATION CABLES, Acc. to BS 5308 PART 1 TYPE 2RE-2Y(St)HSWAH,SINGLE & MULTI-TRIPLE, PE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHEDRE-2X(St)HSWAH,SINGLE & MULTI-TRIPLE, XLPE INSULATED, COLLECTİVE SCREENED, LSZH SHEATHED These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petrochemistry industry plants, power plants, natural gas and petroluem plants, etc... . Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. No corrosive gases are emitted in the event of fire. With blue sheath it is suitable for intrinsically safe systems. The armour above the inner sheath protects the cable from mechanical shocks. These cables are recommended for direct burial. They are for indoor and oudoor installation, in dry and wet locations; on racks, trays, in conduits. Conductor: Plain annealed copper wire, BS 6360, 0,50 mm2 and 1,0 mm2 solid, 0,50 mm2 and, 0,75 mm2 flexible or 1,5 mm2 stranded Insulation (2Y): PE compound, BS 6234 Type03 (RE-2Y….) Insulation (2X): XLPE compound, GP8, BS 7655 (RE-2X….) Core identification: Black / White / Red cores are numbered, (1-1-1, 2-2-2,…), Note: Other core configurations manufactured upon request Triple: Three conductors twisted to a triple Lay-up: Triples laid up in layers of optimum pitch Separator: Polyester tape Screen: AL-PES tape over tinned copper drain wire 0,50 mm2 Bedding: LSZH compound, Black Armour: Galvenized round steel wire, BS EN 10257-1 Outer sheath: LSZH compound, LST1, BS 7655, LSZH : Low Smoke Zero Halogen Sheath colour: RAL 9005, Black or RAL 5015, Blue Standard: Designed acc. to BS 5308 Part 1 Type 2 Insulation thickness: 0,50mm2 : 0,50mm, 1,0mm2 : 0,60mm, 0,50mm2 : 0,60mm, 0,75mm2 : 0,60mm, 1,50mm2 : 0,60mm Conductor class, BS 6360: 0,50mm2 : Class 1, 1,0mm2 : Class 1, 0,50mm2 : Class 5, 0,75mm2 : Class 5, 1,5mm2 : Class 2 Conductor resistance: 0,50mm2 : 36,8 Ω/km, 1,0mm2 : 18,4 Ω/km, 0,50mm2 : 39,7 Ω/km, 0,75mm2 : 26,5 Ω/km, 1,5mm2 : 12,3 Ω/km Insulation resistance: Min. 5000 MΩ.km Capacitance unbalance: (1 kHz) : max. 250 pF/250 m L / R (ratio) (max.): 0,50mm2 : 25 µH/Ω, 0,75mm2 : 25 µH/Ω, 1,0mm2 : 25 µH/Ω1,5mm2 : 40 µH/Ω Rated voltage: 300/500V Test voltage: Urms core-core : 1000 V, Urms core-screen : 1000 V Temperature range (2Y): operation : - 40 oC ~ + 70 oC, ınstallation : - 5 oC ~ + 50 oC Temperature range (2X): operation : - 40 oC ~ + 90 oC, ınstallation : - 5 oC ~ + 50 oC Min. bending radius: 8 x D Flame retardance test: IEC 60332-1 & BS EN 60332-1, IEC 60332-3 & BS EN 50266-2-4 Smoke density test: IEC 61034-2 & BS EN 61034-2 Halogen-free properties test: IEC60754-1/2 & BS EN 50267-2
LIHCH

LIHCH

HALOGEN-FREE SCREENED DATA CABLES These halogen-free screened flexible control and connecting cables are used in instrumentation and control engineering where low current consumptionsare required and transmission of the data must be continuous , for example in industrial electronics, information and transmission systems office machines. And also consisting of tinned copper wires as screen provides protection against external pulses. These cables are used at schools, airpots, hospitals, etc. and in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. These cables are not intended for outdoor or underground installation. Conductor: Flexible copper wires, plain;, IEC 60228 Class 5, TS/DIN EN 60228 Class 5 Insulation: HFFR compound, HI2 , VDE 0207-23 Core identification: According to DIN 47100 or TS/DIN EN 50334, black cores with white numerals Lay-up: Cores laid up in layers of optimum pitch Separator: Polyester tape Screen: Braid of tinned Cu wires, 85% coverage Outer sheath: HFFR compound, HM2, VDE 0207-24, HFFR: Halogen-free flame retardant Sheath colour: RAL 7001,Grey Standard: VDE 0812 & VDE 0814 & VDE 0245 Insulation resistance: Min. 200 MΩ.km Mutual Capacitance: d/d-c/c 0,14 mm2 : max. 120 pF/m, d/d-c/c ≥ 0,25 mm2 : max. 150 pF/m, d/e-c/s 0,14 mm2 : max. 240 pF/m , d/e-c/s ≥ 0,25 mm2 : max. 270 pF/m Inductance: ~ 0,67 Mh/km Impedance: ~ 80 MΩ Rated voltage: 0,14 mm2 : 350 V (for peak voltage), ≥0,25 mm2 : 500V, Uo/U ≥0,50 mm2 :300/500V Test voltage: 0,14 mm2 : 1200 V, ≥0,25 mm2 : 1500V, ≥0,50 mm2 : 2000V Temperature range: Fixed: - 30 oC ~ + 70 oC, Mobile: - 5 oC ~ + 50 oC Min. bending radius: Fixed: 6 x D, Mobile: 12 x D Flame test: IEC 60332-3 & TS/DIN EN 50266-2-4 Smoke density test: IEC 61034-2 & TS/DIN EN 61034-2 Halogen-free properties test: IEC60754-1/2 & TS/DIN EN 50267-2
SY BÜKÜLÜ / SY BENDED

SY BÜKÜLÜ / SY BENDED

STEEL WIRE BRAID SHIP TYPE CABLES,SY- STRANDED CORES 300/500V These cables are mainly used in permanent installations such as e.g. Lighting, power cables in ships. They are very resistant to all conditions in the marine environment such as dry, wet and oil. The steel wire braid serves as protection against mechanical traverse load and act as a magnetic screen against external interference. The galvanised steel wires are free of corresion and oxidation. Conductor: Plain Cu wires, flexible ,IEC 228-5 Insulation: PVC compound Lay-up: Cores laid up in layers of optimum pitch Inner Sheath: PVC compound Screen: Braid of galvanised wires, approx. %85 coverage Outer sheath: Oil and flame resistant special PVC compound Sheath colour: Black Standard: Accoding to VDE 0250 Insulation resistance: >20 MΩ.km Rated voltage: 300/500 V Test voltage: 2000 V Temperature range: Fixed : - 30 oC ~ + 70 oC, Mobile : - 5 oC ~ + 50 oC Min. bending radius: 10 x D Flame retardance test: IEC 60332-1 & EN 50265-2-1