Finden Sie schnell vitamin-test-kits für Ihr Unternehmen: 107 Ergebnisse

KV50-200 MK3 Test System

KV50-200 MK3 Test System

0-50kV output voltage 5kVA output capability Key operated supply switch to prevent unauthorised operation Dual overload protection Variable electronic trip – 10-110% of rated output Voltage and current metering External interlock circuit Zero-volt interlock Visual indication of test piece failure The KV50-200 MK2 Test System is a high power, high voltage ac test set designed for insulation testing. This system is equally suited to both development and routine testing of electrical insulation systems and plant. The equipment consists of a control unit and a separate oil filled high voltage transformer, linked by 5 meter supply and control cables. The control unit is fitted with a comprehensive range of facilities for control, metering and protection. The system includes a secondary tap metering as standard to ensure accurate voltage metering. The output voltage and current are displayed on large, linear analogue instruments, and a variable electronic trip is provided, allowing the trip current to be set to 10-110% of rated output. The high voltage transformer is housed in an oil-filled steel tank fitted with swivel castors for mobility. The units use a low-discharge oil-filled bushing for the HV output. The KV50-200 MK2 Test System is equally suited to testing capacitive, resistive or inductive test objects. The output of the units are protected by variable electronic trips monitoring the output current, and a fixed over-current trip on the primary of the output transformer. The variable trip is adjustable in 10% steps between 10% and 110% of the rated output current. The input and control supplies are protected by fuses. An earth terminal is provided on the transformer which must be connected to a low impedance local earth. WEIGHT 37 kg DIMENSIONS 370 × 480 × 290 mm TRANSFORMER WEIGHT 220 kg TRANSFORMER DIMENSIONS 570 x 500 x 1020 mm SUPPLIED ACCESSORIES Supply lead Spare fuse set Operating manual Earth lead
Vitamin C Phosphatester

Vitamin C Phosphatester

Off-White oder Hellgelb, geeignet für die Verwendung in der Mischung des landwirtschaftlichen Futterrohstoffs
Alka-M-Photometertabletten

Alka-M-Photometertabletten

Zur photometrischen Bestimmung der Säurekapazität. Artikelnummer: 1001201 Verpackungseinheit: 1,250 Stück,STÜCK,
Minikit Gesamthärte

Minikit Gesamthärte

Für die MINIKITs stehen verschiedene Testverfahren zur Verfügung: Wählen Sie zwischen manuellen Testverfahren, dem Trübungs- oder Tablettenzählverfahren oder dem sogenannten Speedtest. Artikelnummer: 1004101 Verpackungseinheit: 1STÜCK,
Mera 3 Fort

Mera 3 Fort

Specifically formulated to prevent nutrient deficiencies and support women who are planning a pregnancy, pregnant, or lactating. Mera 3 Fort tablets help meet the daily requirements for essential nutrients, promote immunity, and contribute to overall well-being. Enriched with Folic Acid, B6 and B12 vitamins, which play crucial roles in metabolic processes, supporting the development of the baby’s nervous system and brain while reducing the risk of neural tube defects, and alleviates feelings of tiredness and fatigue.
Mera Pregna

Mera Pregna

Designed to meet the daily nutritional needs of women during stages of pregnancy and lactation, Mera Pregna is an all-in-one blend of 24 key vitamins and minerals. Precisely formulated, it provides essential nutrients at levels above the Recommended Daily Allowance (RDA), all within safe limits for pregnancy. Mera Pregna includes 600 mcg of folic acid, along with iron, vitamins of B and other essential core nutrients in the most bioavailable format, to support fertility and maternal health.
Meratrum Vitamin D3 Spray

Meratrum Vitamin D3 Spray

Designed as a convenient, oil-based sublingual spray Meratrum Vitamin D3 delivers 1000 IU of vitamin D3 per puff. known for its vital role, Vitamin D3 maintains levels and enhances absorption of calcium, supports bones, teeth, muscle health, and boosts immune system activity. This innovative approach of Vitamin D3 supplementation requires no water and avoids any oily sensation through a fine dispersion. The dynamic technology implemented in Meratrum Vitamin D3 spray allows you to adjust your dose easily, offering either 1000 IU with a single puff or 2000 IU with two puffs.
Meratrum PREGNA 3

Meratrum PREGNA 3

Utilizing an advanced 3-layer tablet technology, Meratrum PREGNA 3 delivers a blend of nutrients with a precise timed-release mechanism which ensures that essential vitamins and minerals are available to support both maternal and fetal health throughout the day. Designed to release its contents at different intervals, to prevent ingredient interactions and ensure maximum nutrient availability. Delivers immediate boost of essential vitamins and minerals through the Fast layer which includes Folate, Vitamin B12, and Vitamin B6. Supports blood health and immune function through the Steady release of Iron and Vitamin C. And ensures sustained release of nutrients crucial for fetal development utilizing a Retard layer of Iodine, Vitamin D, Zinc, Lutein and Calcium
ART3V RELAY TEST SYSTEM

ART3V RELAY TEST SYSTEM

3-f Voltage output from 1-f supply 0-450V f-N output voltage 20VA/phase maximum output Variable Frequency 30-999.9Hz Phase shift ±180.0° Multi-function timing system USB keyboard for comment USB data storage. Ideally suited to testing G59 & G99 schemes Step change of phase and df/dt Large 6.5” back-lit colour LCD Automatic mains voltage selection Fully Programmable test procedures Rugged case and weighs under 9kg The new ART3V Relay Test System brings new features to our range of relay test equipment making it far more adaptable. The new output voltages are higher and have a finer level of accuracy and control. The new full colour LCD provides more test detail, making it easy to understand. The ART3V user interface is an improvement of the DVS3 mk2 allowing simple testing of complex voltage and loss of mains protection systems. The ART3V has vastly improved accuracy, stability, and features. Designed to be the trusted and reliable voltage source for relay testing. The ART3V has been designed using the latest digital technology to generate a highly stable and accurate output with very low distortion. Each phase output is individually adjustable for voltage, frequency and phase angle. The unit is controlled by a simple user interface within defined menus. Values may be either typed in at the capacitive keypad or finely varied using a smooth rotary encoder. Bespoke test procedures can be created for step changes of any output variable at set times or with automatic timing of the response of the relay under test. The ART3V has a colour back-lit display to provide an easy to read user interface. Menu options are selected by dedicated buttons on the panel, allowing easy mode change. All information is displayed including contact set status, and a phasor diagram. The ART3V Relay Test System is ideally suited for testing G59/G99 protection, including loss of mains protection. Vector surge and df/dt (ROCOF) relays can be simply tested and timed, as well as other protection requiring one to three voltages, including: Under and over frequency relays Under and over voltage relays Synchronising relays df/dt & ROCOF relays Vector surge relays Transducers In conjunction with the ART3C or a current source (such as the 200ADM-P), the ART3V can be used to test protection circuits, including: Directional relays Distance protection Phase angle relays Power relays Power transducers Output The output of the ART3V has 4mm safety sockets for phases A, B, C and neutral. The neutral connection may be omitted for a delta connection. The neutrals can be linked for a star connection using the provided accessory. Timing System The timing system on the ART3V is flexible and transparent with different modes of operation. USB Data The ART3V can be connected to a USB keyboard for adding comments to tests. Each test is stored to a USB memory key with each comment. The data is stored in a *.CSV format allowing it to be opened in all types of desktop PC spreadsheet software. Modes of Operation Output Adjust This mode allows full control of frequency, voltage and phase. Phase Lock Mode The frequency and phase of the output can be controlled by an external reference in phase lock mode. The reference may be the mains supply to the ART3V, an external voltage, current. This mode allows testing of directional and distance protection in conjunction with an external current source. Fault Config Mode Fault Config mode allows extra flexibility in testing complex timed events or several sets of values that must be applied to a relay in turn. This mode allows three sets of values to be set in advance (pre-fault, fault, and post-fault values). The ART3V may be set to switch from one state to the next on a change of contact or after a specific time. In addition, the timer may be set to start or stop on any one of the state changes or a change of contact state. This mode allows frequency, phase and voltage to be changed simultaneously if required. Test configurations can be save to USB. More complex configurations can be loaded from the USB, such as a complete G59/G99 relay test, such as relay stability tests. df/dt and ROCOF (Rate Of Change Of Frequency) Loss of mains protection often takes the form of a df/dt relay, sensitive to the rate of change of frequency over time. The ART3V is able to generate a swept frequency output with accurate rates of change of frequency between preset frequencies. WEIGHT 8.9 kg DIMENSIONS 419 × 325 × 195 mm SUPPLIED ACCESSORIES Output lead set Lead set case Mains lead Spare fuse set Operating manual
Ferromera Syrup

Ferromera Syrup

Renowned for its superior taste and high consumer satisfaction, Ferromera Liquid Tonic is a specialized nutritional formula designed to enhance red blood cell production and support crucial metabolic functions. Healthy red blood cells are vital for efficient oxygen delivery, Ferromera’s blend of iron and copper ensures optimal hemoglobin production and iron transport. B vitamins and essential trace elements like zinc and manganese further support effective metabolic processes. Vegetarian friendly and free of allergens, Ferromera Liquid Tonic revitalizes your body, enhances mental performance, and alleviates symptoms of fatigue. Designed to benefit people of all ages, including children, pregnant women and athletes, helping them maintain everyday peak vitality and well-being.
Mera Lutein

Mera Lutein

A potent antioxidant that contributes to the protection of cells from oxidative stress utilizing the powerful features of Vitamin E. It promotes vitality and performance through protection against the damaging actions of free radicals which may occur due to metabolic processes or environmental influences. Regular use of Mera Vitamin E enhances overall performance against daily stressors and environmental challenges
PV CHECK – PV-Installationstester gemäß VDE 0126-23 (EN 62446)

PV CHECK – PV-Installationstester gemäß VDE 0126-23 (EN 62446)

Isolationswiderstandsmessung 250/500/1000V DC Durchgangsprüfung / Niederohmmessung Rpe Leerlaufspannungsmessung Uoc bis 1000V DC Kurzschlussstrommessung Isc bis 10A DC automatische Anzeige der Spannungspolarität Ergebnisanzeige OK / Nicht OK Funktionstest & Leistungsmessung DC bis 100A DC Wirkungsgrad (optional mit Referenzzelle HT304N) Temperaturmessung (optional mit Fühler PT300N) Einstrahlungsmessung (optional mit Referenzzelle HT304N) Messwertspeicher für 999 Messungen USB Schnittstelle Mit dem PV-CHECKs können alle geforderten elektrischen Sicherheitsprüfungen an Photovoltaik-Systemen einfach, sicher und normgerecht nach VDE 0126-23 (EN 62446) durchgeführt werden. Die einfache Bedienung (Autosequenz Messablauf) ermöglicht eine sichere, zuverlässige und schnelle Durchführung aller geforderten Messungen (automatischer Prüfablauf): Kurzschlussstrom → Leerlaufspannung → Isolationsmessung → Niederohmmessung Funktionen: Isolationswiderstandsmessung 250/500/1000V DC mit Riso Einzelmessung + oder – gegen Erde Durchgangsprüfung / Niederohmmessung Rpe Leerlaufspannungsmessung Uoc bis 1000V DC Kurzschlussstrommessung Isc bis 15A DC automatische Anzeige der Spannungspolarität Ergebnisanzeige OK / Nicht OK Funktionstest & Leistungsmessung DC bis 100A Datenlogger Funktion DC Wirkungsgrad (optional mit Referenzzelle HT304N) Temperaturmessung (optional mit Fühler PT300N) Einstrahlungsmessung (optional mit Referenzzelle HT304N) inkl. Messwertspeicher für 999 Messungen inkl. USB Schnittstelle
Vitamin A Acetat

Vitamin A Acetat

325.000 IE/g /500.000 IE/g, gelbes feines Pulver; 1.000.000 IE/g, hellgelbes Oli; 2.800.000 IE/g, kristallines Pulver;
Vitamin B1 Thiaminmononitrat

Vitamin B1 Thiaminmononitrat

98.0%-101.0% Weißes oder fast weißes kristallines Pulver Beteiligen Sie sich an der Bildung von Coenzymen im Körper, halten Sie den Kohlenhydratstoffwechsel, Rohstoffe für Lebensmittel und Gesundheitsprodukte aufrecht.
HV TROLLEY2 High Voltage AC Test System

HV TROLLEY2 High Voltage AC Test System

20kVA output capability 0-3kV to 0-15kV options available Accurate digital metering Key operated supply switch Dual overload protection Variable electronic trip 10-110% of rated output Voltage and current metering Optional 5s – 5min test timer External 24V interlock and zero-volt interlock Emergency stop switch The HV trolley2 series of units are high power AC flash test sets with a 20kVA output capability. Single Trolley Version The maximum output voltage can be customised to be any voltage up to 15kV. The unit is housed in a rugged aluminium enclosure with a cover to protect the control panel. It is mounted on wheels to allow easy movement within a production environment. The HV trolley2 is provided with accurate digital voltage and current metering and a variable electronic trip. An external interlock input is also fitted to the unit. Outputs are provided to drive 24V warning beacons. The HV output is connected to the test object by a high voltage cable 5m long.
Vitamin B2 98% (Riboflavin)

Vitamin B2 98% (Riboflavin)

CAS-Nr. 83-88-5 98,0% ~ 102,0% Orange Gelb Kristallines Pulver Es kann als Lebensmittelzusatzstoff und pharmazeutischer Rohstoff verwendet werden.
Alka-M-HR Photometer

Alka-M-HR Photometer

Zur photometrischen Bestimmung der Säurekapazität. Artikelnummer: 2224525 Verpackungseinheit: 1,250 Stück,STÜCK,