OECD 439 - Human Skin Irritation / Epiderm: OECD 439, in vitro Test - INVITRO-CONNECT GmbH
Test Guideline No. 439
OECD 439 / in Vitro Skin Irritation Reconstructed Human Epidermis Test Method
Fast Project Execution: personal - competent - reliable --> contact@invitro-connect.com
INVITRO-CONNECT GmbH offers various test strategies without animal testing for examining Skin Irritation:
- OECD 439 / Skin Irritation Test (SIT) in a Reconstructed Human Epidermis (RhE) Model -
Skin Irritation in the regulatory hazard classification and labeling context is defined as the production of reversible damage to skin following a defined chemical exposure. The Skin Irritation Test (SIT) is an in vitro, non-animal test designed to identify those chemicals and mixtures capable of inducing moderate skin irritation (UN GHS Category 2 Skin Irritants1), and to discriminate UN GHS Category 2 Skin Irritants from UN GHS 3 Mild Skin Irritants as well as those not requiring classification for skin irritation potential.
This test method is useful for regulatory classification and labeling of chemicals and mixtures, and depending upon the regulatory jurisdiction and framework the test results may be used as standalone or to support a weight of evidence approach. Since skin irritation in vivo typically results from chemical-induced cell damage and subsequent inflammatory cascade, this test method provides a mechanistically-relevant measurement of cell viability in reconstructed human epidermis (RhE) tissues after a single topically-applied chemical treatment, relative to negative control-treated tissues. Chemicals which reduce relative viability to ≤ 50% would be classified as an irritant (and a potential corrosive), while those which result in a relative viability > 50% would not be classified as a skin irritant in accordance with UN GHS Category 2.
INVITRO-CONNECT GmbH has extensive expertise with a wide variety of reconstructed skin-based protocols.
NOTE: Since this test method does not discriminate UN GHS categories 1 and 2, an irritant prediction by this test method should be followed up with a test for potential skin corrosion, using any of the validated corrosivity test methods. 1) Corrositex Membrane Barrier Time Monitor Corrosion Test Method and 2) In Vitro Skin Corrosion Test using a Reconstructed Human Epidermis (RhE) Model
A variety of other protocols are available to evaluate for potential skin irritation to support product development, product stewardship, candidate formulation selection and other non-regulatory applications, and can provide a rank ordering of skin irritation potential. A variety of protocols allow for evaluation of mild formulations: 1) Time-to-Toxicity ET50 Screening protocol, and 2) Cytokine Expression Assay for Mild Products and for moderate to corrosive products and mixtures: 3) In Vitro Skin Irritation / Corrosion Screen.
For more information please contact INVITRO-CONNECT GmbH for assistance in developing specialized protocols for your test materials.
INVITRO-CONNECT GmbH:
Fast Project Execution: personal - competent - reliable --> contact@invitro-connect.com
More than 80 test laboratories - Product safety - Regulatory service - In vitro tests - All OECD tests for pharmaceuticals, chemicals, medical devices and cosmetics - Study monitoring, MSDS etc.